WARNINGS
- For any eventual regulation, setting or parts
replacement not foreseen in this manual,
please contact the Manufacturer or Seller’s
personnel.
- Before carrying out any replacement make
sure that:
①
the main switch is “OFF”.
Filling the tanks with water and detergent
Fill the tanks with water and detergent in the fol-
lowing way:
①
Stop the machine by turning the main switch
to OFF
⑭
⑮
Fill the tanks
WARNINGS
- Never use distilled water! The machine may not
run correctly.
Water supply from the water main
⑯
Connect a supply hose (not included) to the
water inlet of the unit and to the water supply.
⑰
Open the water supply.
Boiler steam blow-off
Follow the instructions below:
⑤
A few minutes before the end of the work
shift, turn off the boiler by pressing the BOILER
START luminous green push-button.
⑨
Keep on using the steam gun until the pressure
gauge indicates a value of 0-1 BAR;
⑬
Carefully open the boiler drain cock, situated
on the machine right side and drain all the
water from the boiler into a suitable container;
⑬
Once the water has been drained up
completely, close the cock;
MACHINE USE
Description of the start sequence
After carrying out all the connections and the pre-
ventive inspections described in the previous chap-
ters, start the machine according to the following
instructions:
1)
⑤
Before starting the generator, fill the tanks
up to the level with water and detergent.
2)
⑨
Turn the main switch situated on the control
panel to ON.
3) Press the BOILER START push-button on the
control panel board.
4) Press the GUN START push-button on the
control panel board.
5)
⑬
If the water level in the boiler is already
correct, the thermoregulator will indicate
the temperature value previously set by the
operator after approx. 7-10 minutes. At this
point, the steam gun can be used.
6)
⑬
If the display show H2O and it flashes and
an acoustic alarm is heard, it means that there
is no water in the tank. Fill the tank (see “Filling
the tanks with water and detergent”).
Machine stop
At the end of the work shift, stop the machine in the
following way:
1)
⑤
Switch off : BOILER START push-button
2)
⑥
Switch off : GUN START push-button.
3)
①
Turn the main switch on the control panel bo-
ard to OFF.
4) Unplug the machine.
WARNINGS
- In order to suddenly stop the machine at any
time, turn the main switch on the control panel
to OFF.
- During the machine functioning, it is strictly
forbidden to remove the safety devices
assembled by the Builder on the machine in
order to protect the operator while performing
his tasks.
- Only skilled and qualified operators must use
EN