background image

19

EN

ROUTINE MAINTENANCE

Perform the operations described in the 

“STOP”

 

paragraph, following the chart shown below.

MAINTENANCE 

SCHEDULE

JOB

After every use

  Check the power cable, high-pressure hose, connections, spray gun and lance hose.

  If any of these is damaged, do not use the high-pressure cleaner and contact a 

Skilled 

Technician

.

Weekly

•  Clean the water inlet filter (21).

  Unscrew the quick-fit connection (23) and take out the filter (21). Generally speaking, 

to clean this all that need be done is pass the filter under a jet of running water 

or blow on it with compressed air. In the most difficult cases, use an anti-scale 

product or replace the filter. To buy spares contact an authorised after-sales centre. 

Fit the filter back on and screw the quick-fit connection back on.

Monthly

•  Clean the nozzle.

  Generally speaking, to clean the nozzle, it is enough to pass the pin (12) provided 

through the nozzle hole. If this is not successful, change the nozzle. Buy this from an 

authorised after-sales centre. The nozzle can be changed using a 14 mm wrench (not 

supplied).

•  Clean the detergent suction filter (16)

.

  Generally speaking, to clean the filter, all you need do is pass it under a jet of running 

water or blow it with compressed air. In the most difficult cases, use an anti-scale product 

or replace it. Only buy spares from authorised after-sales centres.

•  Check the pump oil level 

[ETM 150 PRO].

  Use the indicator (5) 

(fig. 1)

. If topping up is required, contact a  

Skilled Technician

SPECIAL MAINTENANCE

Special maintenance jobs must only be performed by a 

Skilled Technician, 

following the table below 

(indicative data).

MAINTENANCE 

SCHEDULE

JOB

Every 200 hours

•  Check the pump (water) hydraulic circuit.   •  Check the pump fastening.  

Every 500 hours

•  Pump oil change.

•  Check the pump suction/delivery valves.

•  Check the tightness of the pump screws.

•  Check the pump regulation valve.  

•  Check the safety devices.

TROUBLESHOOTING

PROBLEMS

CAUSES

REMEDIES

When the switch (1) is 

moved to position 

“1”

the high-pressure cleaner 

does not start.

Tripping of system cutout device to 

which the high-pressure cleaner is 

connected (fuse, RCCB, etc.).

Reset the cutout device.

IN CASE THIS TRIPS AGAIN, DO NOT USE THE 

HIGH-PRESSURE CLEANER AND CONTACT A 

SKILLED TECHNICIAN.

The plug is not properly fitted.

Disconnect the plug and fit it back correctly.

(continued on next page)

Summary of Contents for ETM Series

Page 1: ...MyjkiElektryczneZimnowodne Instrukcja Obs ugiiKonserwacji RU IT ATTENZIONE Leggere le istruzioni prima di utilizzare la macchina EN WARNING Readtheinstructionsbeforeusingthe machine FR ATTENTION Lire...

Page 2: ...ETM 150 PRO ETM 150 PRO ETM 150 X ETM 150 X...

Page 3: ...ETM 150 PRO 1 3 1 4 2 6 7 8 5...

Page 4: ...2 23 21 22 20 9 10 11 12 13 15 14 18 19 S A...

Page 5: ...3 11 16 17 A B 24 17 25 17...

Page 6: ...4 1 5 m 4 9 ft G 26...

Page 7: ...5 D B F E C...

Page 8: ...Pa 150bar 2176psi Forzadireazionesull idropistola 27 9N Livellodipressionesonora Incertezza 82 2dB A 0 8dB A 73 2dB A 0 8dB A Livellodipotenzasonora 96dB A 86dB A Vibrazionesistemamano bracciooperator...

Page 9: ...lastica per fissaggio tubo aspirazione detergente 26 Disconnettore di rete idrica tipo BA non in dotazione DISPOSITIVI DI SICUREZZA Protettore amperometrico Dispositivochearrestailfunzionamentodell id...

Page 10: ...iletto dell idropistola 9 e serrare a fondo con due chiavi fisse da 22 mm non in dotazione Operazione D di Fig 6 Inserireilfiltro 21 nelraccordoingressoacqua 20 Inserirelaguarnizione 22 nelraccordorap...

Page 11: ...ce portando l interruttore generale 1 in posizione 1 ed azionare la leva 19 l aspirazione e la miscelazione avvengono automaticamente al passaggio dell acqua Per arrestare l erogazione del detergente...

Page 12: ...tazione Qualora non si ottengano risultati apprezzabili sostituire l ugello rivolgendosiperl acquistodelricambioaduncentrodiassistenzaautorizzato L ugello sostituibile sfruttando una chiave da 14 mm n...

Page 13: ...Operazione G L idropulitricenonraggiunge la massima pressione Valvoladiregolazioneimpostataper unvaloreinferioreaquellomassimo Ruotare in senso orario la manopola 6 Testina portaugello 11 in bassa pr...

Page 14: ...funzionamento Intervento dispositivo di protezione dell impianto a cui collegata l idropulitrice fusibile interruttore differenziale ecc Ripristinare il dispositivo di protezione IN CASO DI NUOVO INT...

Page 15: ...actionforceonthegun 27 9N Soundpressurelevel Uncertainty 82 2dB A 0 8dB A 73 2dB A 0 8dB A Soundpowerlevel 96dB A 86dB A Operator arm hand system vibration Uncertainty 2 3m s2 0 24m s2 WEIGHTANDDIMENS...

Page 16: ...ticclampforfasteningthedetergentsuction hose 26 BAtypewatermainsdisconnector notsupplied SAFETY DEVICES Ampere cut out protection device This device stops the high pressure cleaner operation in the ev...

Page 17: ...up the connection 13 of the high pressure hose to the thread of the spray gun 9 and tighten well using two 22 mm fixed wrenches not supplied Operation D in fig 6 Fitthefilter 21 inthewaterinletconnect...

Page 18: ...head 11 as shown in fig 3 position A Startthehigh pressurecleaneragain movingthemasterswitch 1 toposition 1 andoperatethelever 19 suction and mixing occur automatically as the water flows through Tost...

Page 19: ...t supplied Clean the detergent suction filter 16 Generally speaking to clean the filter all you need do is pass it under a jet of running waterorblowitwithcompressedair Inthemostdifficultcases useanan...

Page 20: ...ged Follow the indications of the ROUTINE MAINTENANCE paragraph Detergent too viscous UseadetergentrecommendedbytheManufacturer and dilute in accordance with plate instructions Nowatercomesoutofthe no...

Page 21: ...a 150bar 2176psi Force de r action sur le pistolet haute pression 27 9N Niveaudepressionsonore incertitude 82 2dB A 0 8dB A 73 2dB A 0 8dB A Niveau de puissance sonore 96dB A 86dB A Vibration du syst...

Page 22: ...OSITIFS DE S CURIT Coupe circuit amp rem trique Ce dispositif arr te le fonctionnement du nettoyeur haute pression en cas d absorption excessive de courant lectrique S il intervient il faut proc der d...

Page 23: ...fig 6 Ins rer le filtre 21 dans le raccord d entr e de l eau 20 Ins rer le joint 22 dans le raccord rapide d entr e de l eau 23 et le visser au raccord 20 Op ration A de la fig 2 FONCTIONNEMENT OP RAT...

Page 24: ...l interrupteur g n ral 1 sur 1 et actionner la g chette 19 l aspiration et le m lange se produisent automatiquement au passage de l eau Pour arr ter la distribution de d tergent et reprendre le foncti...

Page 25: ...nt remplacerlabuseens adressantpourl achatdelapi ce de rechange un centre d assistance agr La buse peut tre remplac e en utilisant une cl de 14 mm non fournie Nettoyage du filtre d aspiration du d ter...

Page 26: ...ettoyeur haute pression n atteint pas la pression maximum Soupape de r gulation param tr e sur une valeur inf rieure celle maximum Tourner la manette dans le sens des aiguilles d une montre 6 La t te...

Page 27: ...rit de l installation auquel le nettoyeur haute pression est reli fusible disjoncteurdiff rentiel etc s est d clench R armer le dispositif de protection EN CAS DE NOUVEAU D CLENCHEMENT NE PAS UTILISER...

Page 28: ...150bar 2176psi Fuerzadereacci nenlahidro pistola 27 9N Niveldepresi nsonora incertidumbre 82 2dB A 0 8dB A 73 2dB A 0 8dB A Niveldepotenciasonora 96dB A 86dB A Vibraci n sistema mano brazo operador In...

Page 29: ...nistrado DISPOSITIVOS DE SEGURIDAD Protector amperom trico Dispositivo que detiene el funcionamiento de la hidrolavadora en caso de elevada absorci n de corriente el ctrica Al realizar la intervenci n...

Page 30: ...con dos llaves fijas de 22 mm no suministradas Operaci n D de Fig 6 Introducir el filtro 21 en el racor entrada agua 20 Introducir la junta 22 en el racor r pido de entrada agua 23 y enroscarlo al ra...

Page 31: ...n A Volver a arrancar la hidrolavadora llevando el interruptor general 1 a la posici n 1 y accionar la palanca 19 la aspiraci n y la mezcla se producen autom ticamente al pasar el agua Para detener el...

Page 32: ...do Si no se obtienen resultados apreciables sustituir la boquilla dirigi ndose a un centro de asistencia autorizado para comprar el recambio La boquilla se puede sustituir con la ayuda de una llave de...

Page 33: ...G La hidrolavadora no alcanza la presi n m xima V l v u l a d e re g u l a c i n seleccionada para un valor inferior al m ximo Girar la perilla 6 en sentido horario Cabezadelportaboquilla 11 en bajapr...

Page 34: ...a se para durante el funcionamiento Intervenci n dispositivo de protecci n de la instalaci n al cual est conectada la hidrolavadora fusible interruptor diferencial etc Restablecer el dispositivo de p...

Page 35: ...r 2176psi Zp tn s lanahydropistoli 27 9N Hladinaakustick hotlaku Pochybnost 82 2dB A 0 8dB A 73 2dB A 0 8dB A Hladinaakustick hov konu 96dB A 86dB A Vibracenaruku ramenoobsluhy Pochybnost 2 3m s2 0 24...

Page 36: ...sou st dod vky BEZPE NOSTN ZA ZEN Amp rmetrick ochrann za zen Za zen kter vypne isti v p pad p li n ho odb ru elektrick ho proudu V p pad jeho z sahu postupujte n sledovn oto te hlavn vyp na 1 do polo...

Page 37: ...rychlospojce pro p vod vody 23 hadici za pou it b n zahradn rychlospojky Operace F Obr 6 Otev ete kohoutek pro p vod vody a zkontrolujte jestli z n ho nekape voda V p pad p ipojen k vodovodn s ti pitn...

Page 38: ...ho vyp na e 1 do polohy 0 a z sahem na hlavici 11 jak je to zn zorn no na Obr 3 Poloha B P ERU EN PROVOZU S pracovn m tlakem nad 20 bar 290 psi se v p pad uvoln n p ky 19 hydropistole pomoc za zen To...

Page 39: ...vody nebo ho profouknout stla en m vzduchem V p pad velk ho za pin n pou ijte prost edek na odstran n vodn ho kamene nebo filtr vym te pomoc n hradn ho d lu kter si mus te koupit v autorizovan m servi...

Page 40: ...ist c ho prost edku 16 je ucpan i te se pokyny uveden mi v odstavci B N DR BA Pou it prost edekjep li visk zn Pou ijteprost edekdoporu en v robcemadodr ujte pom ry ed n uveden na t tku Z trysky nete...

Page 41: ...150bar 2176psi ReaktionszeitderDruckpistole 27 9N Schalldruckpegel Unsicherheit 82 2dB A 0 8dB A 73 2dB A 0 8dB A Schallleistungspegel 96dB A 86dB A VibrationSystemHand ArmBediener Unsicherheit 2 3m s...

Page 42: ...ung des Reinigungsmittelansaugschlauchs 26 Wassernetzsystemtrenner Typ BA nicht mitgeliefert SICHERHEITSVORRICHTUNGEN Amperometrische Schutzvorrichtung Es handelt sich um eineVorrichtung die den Betri...

Page 43: ...s 14 andenWasserausgangsanschluss 7 anschlie en dann anschrauben und anziehen Vorgang E der Abb 6 Den Anschluss 13 des HD Schlauchs an das Gewinde der Handspritzpistole 9 schrauben und mit zwei 22 mm...

Page 44: ...g vorbereitet sein wird auch in diesem Fall den Empfehlungen bez glich der Dosierung folgen die auf dem Schild der Reinigungsmittelpackung angegeben sind Auf den Kopf des D senhalters 11 wie in Abb 3...

Page 45: ...wieder festschrauben Monatlich Reinigung der D se F r die Reinigung reicht es in der Regel aus die mitgelieferte Nadel 12 durch das Loch der D se zu schieben Sollte man keine nennenswerten Ergebnisse...

Page 46: ...en entsprechen DerHochdruckreinigererreicht nicht den H chstdruck Reglerventilaufeinengeringerenalsden H chstwert eingestellt Den Drehknopf 6 im Uhrzeigersinn drehen KopfdesD senhalters 11 inNiederdru...

Page 47: ...Anlage an die der Hochdruckreiniger angeschlossen ist Sicherung Differentialschalter etc Die Schutzvorrichtung r ckstellen BEI ERNEUTEM EINGREIFEN DEN HOCHDRUCKREINIGER NICHT VERWENDEN UND SICH AN EI...

Page 48: ...tupistoletuwodnego 27 9N Poziom ci nienia d wi kowego brak pewno ci 82 2dB A 0 8dB A 73 2dB A 0 8dB A Poziommocyakustycznej 96dB A 86dB A Drganiaramieniaoperatora brakpewno ci 2 3m s2 0 24m s2 MASAIGA...

Page 49: ...zamocowania przewodu zasysania detergentu 26 Roz cznik sieci wodnej typu BA nie dostarczony w wyposa eniu URZ DZENIA ZABEZPIECZAJ CE Ochronnik amperometryczny Urz dzenie zatrzymuj ce funkcjonowanie my...

Page 50: ...AKCESORI W Pod czy cznik z szybkoz czk 15 przewodu 14 do cznika wylotu wody 7 wkr ci i docisn do oporu Czynno E na Rys 6 Wkr ci cznik 13 przewodu wysokoci nieniowego do przewodu do gwintu pistoletu wo...

Page 51: ...iedniorozcie czonymdetergentem r wnie wtymwypadku odnie si dowskaz wek dotycz cych dozowania podanych na etykiecie opakowania detergentu Dzia a na ko paku oprawy dyszy 11 jak na Rys 3 Pozycja A W czy...

Page 52: ...niu Je eli nie udaje si uzyska zadawalaj cych rezultat w nale ywymieni dysz zwracaj csi doupowa nionegoo rodkapomocy technicznej w celu zakupienia cz ci zamiennej Dysz mo na wymieni u ywaj c klucza 14...

Page 53: ...yjka wodna nie osi ga maksymalnego ci nienia Zaw r regulacyjny ustawiony jest na warto ci nienia ni sz od maksymalnej Przekr ci w kierunku zgodnym z ruchem wskaz wek zegara pokr t o 6 Ko pak oprawy dy...

Page 54: ...terwencja urz dzenia ochronnego instalacji do kt rej pod czona jest myjka bezpieczniki wy cznik r nicowy itp Przywr ci dzia ania urz dzenia ochronnego W PRZYPADKU NOWEJ INTERWENCJI NIE U YWA MYJKI I Z...

Page 55: ...5 C 41 F 750l h 198USgph 0 8MPa 8bar 116psi 1 5m 4 9f 600l h 159USgph 15MPa 150bar 2176psi 27 9N 82 2dB A 0 8dB A 73 2dB A 0 8dB A 96dB A 86dB A 2 3m s2 0 24m s2 460x200x325mm 18 1x7 9x12 8in 425x290...

Page 56: ...56 1 2 3 4 5 1 2 3 BA 4 5 ETM 150 PRO 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 BA 1 0 19 10 15 6 18 19 9 2 S...

Page 57: ...57 RU BA C 15 14 7 E 6 13 9 22 D 6 21 20 22 23 20 A 2 14 23 F 6 BA 26 EN12729 5 1 5 4 9 ft G 5 1 0 C 6 1 1 19 1 0 9 10 B 6...

Page 58: ...58 11 1 1 19 6 90 1 0 17 24 25 3 17 16 11 3 A 1 1 19 1 0 11 3 B 20 bar 290 psi 19 Total Stop 19 1 0 14 19 14 4...

Page 59: ...59 RU 21 23 21 12 14 16 ETM 150 PRO 5 1 200 500...

Page 60: ...60 1 1 21 5 G 6 11 3 A 3 B 5 G BA 11 3 B 3 A 16...

Page 61: ...61 RU BA 5 G 1...

Page 62: ......

Page 63: ......

Page 64: ...A Via G Dorso 4 42124 Reggio Emilia ITALY Tel 39 0522 386111 E mail Italia vendite comet re it fax 39 0522 386300 E mail Export export comet re it fax 39 0522 386286 www comet re it 1610 1819 00 03 20...

Reviews: