VOR Test Screen
VOR Test Controls and Selections
Item
Description
Sets Frequency of the ARTS 7000 Generated VOR
signal
During the active test operation fine adjust is
available see below.
Sets the output power of the ARTS 7000 generated
VOR signal.
During the active test operation fine adjust is
available see below.
Sets the Modulation depth of the VOR signal.
During the active test operation fine adjust is
available see below.
Selects the Audio Identification transmission from
the ARTS 7000.
Options are:
Off
,
Tone
(1KHz steady tone) or
Code
(Morse - LSB).
When Code is selected the repetition rate is set at
30 seconds. The user can trigger an immediate
Code transmission by pressing the code button.
Whenever the Code button is pushed the ARTS will
immediately transmit the Code signal.