34
Select function ( UP ARROW for functions 1 to 3 )
4. Execute profile 5. Set profiles
6. Height Correction 7. Set “Ground”
8. Go to “Ground” 9. Encoder
Once in the correct screen, select a number to go to the desired function. An explanation of
each of the functions is given below.
3.5.0
FUNCTION 0 : IEEE ADDRESS
This function allows the user to enter a valid IEEE-488 address for the 6300. This address is
meaningful only if the “IEEE” option is provided on the 6300. A valid address between 1 and
30 may be entered on the screen shown below.
Current IEEE addr = 5
New IEEE addr =
.
3.5.1
FUNCTION 1 : VIEW LIMITS
The 6300 checks both the Target values and the Actual values to determine if they are within
specific limits. These limits can be set by the user. To view these limits, you can press the
Function Select key and then choose Function 1 (View Limits) by pressing “1”. The VIEW
LIMITS screen appears as shown below.
VIEW LIMITS
1. max. knots = 500.0 4. max. feet = 50000
2. min. knots = -200.0 5. min. feet = -2000
3. max. mach = 1.000 6. max. ft/min.= 6000
To exit from this screen, press CANCEL.
For an explanation of the limits please refer to the “Set Limits” function.