background image

Before carrying out any operation on the machine en-

sure that the plug is disconnected from the current and

that the machine is cool.

In order to avoid any electric shocks, electrical parts and

surrounding components must not:

- enter into contact with any type of liquid;

- be manipulated by humid or wet hands;

- be tampered with.

It is forbidden:

- to use the machine near flammable substances and/or

explosives and/or in an atmosphere with any risk of

fire;

- to use unoriginal spare parts;

- to carry out any type of technical modification not co-

vered in the normal procedures of diagnosis and re-

pair.

In case of fire, use carbon dioxide (CO

2

). Extinguishers.

Do not use water or powder extinguishers.

If an operation or intervention not foreseen should be

carried out, following a different procedure than that in-

dicated in the manual, please contact Lavazza technical

service before starting.

Structural damage, modifications, tampering, alterations

or improper repairs could compromise the safety of the

machine.

Attention

Any operation taken by the technician on the elec-

tronics of the machine when the machine is powe-

red, automatically invalidates any guarantee. The

technician should know that the machine is electri-

cally connected and act accordingly.

2.1. Stop functions

La macchina si arresta portando l’interruttore generale

su “0” (OFF).

2.2. Safety devices

The machine/s described in this publication, are desi-

gned in compliance with the specific standards in force

(CEI EN 60335-1) and therefore have measures of pro-

tection in all the potentially hazardous parts.

A thermal protector avoids any overheating of the

boiler.

A 150°C safety valve

ensures that the pressure in the

boiler does not exceed 2 bars.

Attention

Do not change, eliminate or by-pass the safety de-

vices in order to not cause serious risks to health

and safety.

2.3. Residual risks

The careful hazardous analysis performed, has allowed

most of the risks connected with operating and mainte-

nance machine conditions to be eliminated. Lavazza re-

minds the user that the instructions, procedures and

recommendations contained in this manual should be

strictly followed, and comply with the safety rules in

force, including the use of provided protection devices,

both integrated in the machine and individual.

This chapter illustrates the risks that the user may incur

if he does not comply with the specific safety rules as

described in this booklet.

- La machine must be connected to an earthed installa-

tion.

If it is not done, the appliance can become a source of

dangerous electrical discharges as it is no longer able

to discharge electricity to earth.

- Be careful with the hot water and steam pipes (only

LB2801 and LB2811 models).

During use the hot water pipe may overheat, thus be-

coming a source of danger.

Handle these parts carefully .

- Never direct steam or hot water jets directly on parts of

the body.

- Be careful with the outer surfaces of the brewing unit.

During normal operation, the brewing unit also over-

heats, thus becoming a source of potential hazard. Be

careful not to come into contact with the outer surfa-

ces of the brewing unit.

- Do not work on the machine when it is powered.

Before carry out any operations on the machine, di-

sconnect it from the electrical network.

- Do not use water jets for washing any part of the ap-

pliance because running water can seriously damage

electrical and electronic components.

- Never work on the hydraulic system before having em-

ptied it.

All operations regarding the hydraulic system and its

boiler have to be avoided when there is still water and

pressure in the system. You must therefore empty it

beforehand, closing the mains tap and dry-running the

brewing unit, hot water pipe, cappuccinatore or steam

pipe for a short time .

Switch the machine off.

When the pressure is at zero, completely empty the

boiler, by opening the specific valve located on the

lower part of it. If the above procedure is not correctly

Manual code 10066574 / Rel. 2.00 / February 2012

7

Maintenance manual for technical assistance

Summary of Contents for LB 2801

Page 1: ...LB 2800 2801 2810 2811 MAINTENANCE MANUAL FOR TECHNICAL ASSISTANCE MANUAL CODE 10066574 REL 2 00 FEBRUARY 2012...

Page 2: ...0118 LB 2810 Machine code 10080005 LB 2811 Machine code 10080023 Manual code 10066574 Rel 2 00 Edition 02 2012 www absoluteaftersales it Copyright LAVAZZA S p A Tel 0039 011 2348429 Fax 0039 011 23480...

Page 3: ...s 7 3 HANDLING AND STORAGE 8 3 1 Handling 8 3 2 Storage 8 4 DISMANTLING AND DISPOSAL 8 4 1 Instruction for end of life treatment 8 5 INSTALLATION AND START UP 9 5 1 Unpacking 9 5 2 Positioning 9 5 3 W...

Page 4: ...3 1 Cappuccinatore only LB 2800 LB 2810 models 20 9 3 2 Capsule holder 21 9 3 3 Steam pipe only LB 2800 LB 2810 models 21 9 3 4 Body 21 9 3 5 Steam pipe end only LB 2800 LB 2810 models 21 9 3 6 Brewin...

Page 5: ...the personal protective equipment Warning WARNING messages are displayed before procedu res that if not observed could cause damage to the machine Environment ENVIRONMENT messages are displayed befor...

Page 6: ...th 322 mm Height 470 mm Weight 31 kg 1 3 4 Technical specifications Power supply frequency 50 60 Boiler capacity litres 2 Boiler pressure bar 1 4 max Safety valve calibration bar 2 Supply water pressu...

Page 7: ...ee brewing is taken directly from the heat exchanger During brewing cold water is sent inside of the exchanger by the pump Inside the heat exchanger cold water and the pre exi sting hot water are mixe...

Page 8: ...hine must be put on the pipe 1 3 6 3 Automatic water entry system A E A The automatic water entry system checks the water level in the boiler The system is composed of a probe inserted in the boiler A...

Page 9: ...uge with bottom scale greater than 9 bars to the specific fitting on the water circuit see the hydraulic diagram set the pressure by using the pressure adjusting screw located in the pump A in such a...

Page 10: ...ions could cause accidents during machine operation and maintenance During the repair of the machine all the measures necessary to prevent ac cident must be used The main safety precautions that shoul...

Page 11: ...the risks connected with operating and mainte nance machine conditions to be eliminated Lavazza re minds the user that the instructions procedures and recommendations contained in this manual should...

Page 12: ...product should not be treated as a generic household waste but should be delivered to an authorised local recycling centre of WEEE Collecting the components of the machine in properly separated fracti...

Page 13: ...ditions Attention Sufficient space must be allowed to access the ma chine and the plug to allow the user to move freely and to be able to immediately leave the area in an emergency Prepare a support...

Page 14: ...Attention The hydraulic connection must be made in com pliance with local national rules If an external tank is used the connection pipe bet ween the machine and the tank must not exceed 150 cm For t...

Page 15: ...e circuit so that the brewing units are completely heated Before using the machine dispense few coffees to check the operating pressure of the machine 6 RECOMMENDED TOOLS SET OF FIXED KEYS SET OF ALLE...

Page 16: ...eat this operation for the other dose key When the programming is completed place the pro gramming lever 1 to the OFF position 7 2 2 Programming of cappuccino doses only LB 2800 LB 2810 models Put the...

Page 17: ...crease cold water 7 2 4 Programming of coffee cappuccino sequence only LB 2800 LB 2810 models The machine allows you to decide which sequence to use when dispensing cappuccino In particular there are...

Page 18: ...sed until the LEDs of the keyboard light up the flashing modes of the LEDs indicate the current temperature set temperature the sum of the flashes of every dose key multiplied by the indicated value s...

Page 19: ...et quantity of water is reached dispensing stops automatically Attention Do not touch the hot water pipe because it is a com ponent which reaches high temperatures Dispensing steam only LB 2801 LB 281...

Page 20: ...In the chart below milk temperatures related to the installed reducer are in dicated Temperature chart with and without flow reducers temperatures detected in a pre heated cup 7 2 10 Preparing coffee...

Page 21: ...TED NOT INSERTED JP2 Pre infusion function enabled JP3 Programming key JP4 AEA pump coupling Coffee only Coffee only JP5 Tea key connector JP6 Tea pump coupling JP7 Continuous cycle operation JP8 Mixe...

Page 22: ...way valve 06 Drain tray 07 Pressure gauge 08 Reducer 09 Boiler 10 Brewing unit 11 Steam solenoid valve 12 Safety valve 13 Anti vacuum valve 14 Brewing unit solenoid valve 15 Solenoid valve of Automati...

Page 23: ...intenance 9 2 1 Brewing unit To replace the brewing unit components proceed as fol lows loosen the screw A remove the spring B replace the perforator C if damaged not compliant dispensing loosen the r...

Page 24: ...with comple tely clean and hygienic cloths Attention During cleaning be careful with the tips of the cap sule perforator located inside the clamping ring of the unit 9 3 1 Cappuccinatore only LB 2800...

Page 25: ...ght so that the fatty coffee deposits can dissolve Then rinse them Warning If the capsule holders are not daily cleaned the qua lity of the dispensed coffee and the correct opera tion of the capsule h...

Page 26: ...ean or replace the solenoid valve filter Too much water in the boiler The solenoid valve of the automatic level device is damaged Replace the solenoid valve of the au tomatic level device The heat exc...

Page 27: ...gers and or the heating element Clean the machine The thermostat to protect the heating ele ment is trigged Reset the heating element protection Lime scale has reduced the water circu lation Clean the...

Page 28: ...ged Controllare e pulire il gruppo eroga zione The capsule holder is dirty Check and clean the brewing unit Lower perforators are dirty Clean and replace the perforators if necessary The pressure gaug...

Page 29: ...the dose is too small Check and replace the discharge val ves Water leakage from the unit solenoid valve during coffee brewing or when at resting position Clean and replace the solenoid valve if neces...

Page 30: ...the power supply voltage of the motor is correct The pump works below the no minal capacity The inlet is clogged even partially Clean the pump filter The pump rotates in the wrong direction Check the...

Page 31: ...wing Reduce the water temperature Air pockets in the hydraulic circuit Tighten fittings or connectors which are loose The flow reducer of the brewing unit is unsuitable Replace the flow reducer Manual...

Reviews: