Service Mode

4:5

073  RTC promotion1 “073”>d>hh.mm>%%%>”073”
074 

RTC promotion 1 END “074”>hh.mm>”074”

075  RTC promotion 2 START “075”>d>hh.mm>%%%>”075”
076  RTC promotion 2 END “076”>hh.mm>”076”
077  RTC promotion 3 START”077”>d>hh.mm>%%%>”077”
078  RTC promotion 3 END “078”>hh.mm>”078”
079  RTC promotion 4 START”079”>d>hh.mm>%%%>”079”
080  RTC promotion 4 END “080”>hh.mm>”080”
 

Note 073-080 ranges: d= day of week “0”-”A”; 0=promotion inactive, 1=Sunday,2=Monday, 

 

...7=Saturday, 8=Every day, 9= Monday-Friday only, A=Saturday and Sunday only; hh=”00” 

 

”23”; mm=”00”-”59”; %%% “000” –“999”, “A00” = Free, Default = “000”

081  Promotion %%% for discount input signal (range “000”-“999”; “A00” = Free, default = “000”

Miscellaneous Settings:

082  LSM PIN code (range=”0000”-”9999”, default=”1234”)
083  FSM PIN code (range=0000”-“9999”, default=”0000” (disabled))
084  Default program (range 0-3, 0=none,1=High, 2=Medium, 3=Low, 4=, No Heat, default=”1”)
085  Default program timeout (seconds, range 000-999, default=060)
086  Temperature displayed in °F or °C (0=°F,1=°C, default=0 (display °F))
087  Disable outlet air temperature display (range 0-1,default =0=enabled,1=disabled)
088  Disable buzzer (default =0=enabled,1=disabled)
089  Serial communication enabled (range 0-1, default = 0) (Reserved for future use)

*098  Machine address (range 000-999, default 000) 
*099  Firmware version
*Function available in both “Limited Service Mode” and “Full Service Mode”.

Summary of Contents for CROSSOVER 2.0 Series

Page 1: ...CROSSOVER 2 0 SERIES In a class by itself DRYER OPERATING MANUAL DOC NO 098538 EDITION 4 2018 D R Y E R O P E R A T I N G M A N U A L DOC NO 098538 EDITION 4 2018...

Page 2: ...repair or replace any part of the appliance or attempt any servicing unless specifically recommended in the user maintenance instructions or in published user repair instructions that you understand a...

Page 3: ...ent Installation and service must be performed by a qualified installer service agency or gas supplier GROUNDING INSTRUCTIONS This appliance must be connected to a grounded metal permanent wiring syst...

Page 4: ...Model Numbers Electric DLHF0817EMI DLHF0817E DLHS0817EMI DLHS0817E Gas DLHF0817GMI DLHF0817G DLHS0817GMI DLHS0817G...

Page 5: ...THIS MANUAL MUST BE FOLLOWED AT THE FREQUENCY SPECIFIED FOR PROPER OPERATION OF YOUR MACHINE PLEASE ENTER THE FOLLOWING INFORMATION AS IT APPEARS ON THE MACHINE S DATA PLATE S KEEP THIS MANUAL FOR FUT...

Page 6: ...Contents Control Panels Instructions for Use 1 1 Coin Meter 2 1 Fault Codes 3 1 Services Code 4 1 Preventive Maintenance 5 1...

Page 7: ...nd the drying time designated for each program In the event of faults error codes will be displayed See the fault codes section of this manual Explanation of the control panel A Program selection butt...

Page 8: ...justed with the service menu registers Heating and Cool Down times can also be adjusted using the registers in the service menu During heating the display shows d xx where xx are the remaining drying...

Page 9: ...Coin 1 Value or Coin 2 Value as the coin pulses are received The following instructions show how to set up prices for drying programs 1 To enter programming mode unlock and remove the coin box 2 Press...

Page 10: ...or the base time of the drying program when Amount to start 0 00 00 in token mode This time is credited when a program selection temperature button is pressed for the first time if the remaining dryin...

Page 11: ...s will be displayed in 24 hr format as two digit numbers hh mm Edit these values using the HIGH MEDIUM LOW and NO HEAT buttons 5 Press START to save the changes and exit register 72 This will reset th...

Page 12: ...regarding connecting this signal to the dryer to activate discounts Price Promotion Setup Via External Signal 1 Navigate to Register 081 Promotion for discount input signal as explained in the Service...

Page 13: ...must be called Error Code Cause Action E 00 Machine out of operation E 01 Inlet air temperature limit exceeded E 02 Outlet air temperature limit exceeded E 03 Inlet thermistor short circuit E 04 Outl...

Page 14: ...ault is 1234 3 Press START The display shows 10 the first register available in LSM 4 Use the LOW and NO HEAT buttons to navigate to the desired register 5 Press START to access the register or activa...

Page 15: ...nter for Low temp program Range 0000 to F999 003 Running hour counter for No Heat temp program Range 0000 to F999 004 Total hour counter 00 01 02 03 Range 0000 to F999 005 Total collections counter fi...

Page 16: ...rate of inlet air temperature rise degrees per minute during most recent test Reserved for future use Payment Configuration Registers 030 Coin Mode Token Mode range 0 1 default 0 coin mode When set to...

Page 17: ...perature for No Heat range 0 80C default 0 C 32 F 064 Cool down time for High minutes range 01 10 default 01 065 Cool down time for Medium minutes range 01 10 default 01 066 Cool down time for Low min...

Page 18: ...on for discount input signal range 000 999 A00 Free default 000 Miscellaneous Settings 082 LSM PIN code range 0000 9999 default 1234 083 FSM PIN code range 0000 9999 default 0000 disabled 084 Default...

Page 19: ...ation from lint chamber and temperature sensor area See illustration x x Clean the door gasket Use a soft wash cloth and mild detergent to clean door Every Third Month Disconnect Power Remove lint fro...

Page 20: ...tructed with lint change to a shorter service interval such as every three months A back draft damper that is sticking partially closed can result in slow drying and the shutdown of heat circuit safet...

Page 21: ...Intentionally blank...

Page 22: ...Sales and Administration 516 371 4400 Spare Parts 516 371 2000 Technical Support 516 371 0700 En Mexico 001 800 010 1010 461 Doughty Blvd Inwood NY 11096 laundrylux com...

Reviews: