Service Mode
4. Service mode automatically terminates if no pushbutton is pressed for 60 seconds whenever
the machine is not running.
5. When service modes 20, 21, 22 or 23 are activated a “background timer is started and shall
be used to stop the dryer after running for 90 continuous minutes if the machine has not been
stopped by a press of the Start button.
6. A CPU reset will return the machine’s registers and temperature settings to default values.
The machine will be set to COIN mode and pricing cleared. The statistics (00-19) and RTC/
Promotion registers (72-81) will be unaffected.
Register Assignments
Machine usage registers (default values= “0000” for registers 00-14).
000 Running hour counter for High temp program. (Range: 0000 to F999).
001 Running hour counter for Medium temp program. (Range: 0000 to F999).
002 Running hour counter for Low temp program. (Range 0000 to F999).
003 Running hour counter for No Heat temp program. (Range 0000 to F999).
004 Total hour counter = 00+01+02+03. (Range 0000 to F999).
005 Total collections counter - first 4 digits. (Range 0000 to F999).
006 Total collections counter - last 4 digits (Range 00.00 - 99.99)
(Decimal suppressed in “token” mode).
Error log and coin vault access time stamp registers (time in 24 hour format):
*010 Error code register 1 (Newest error: “010”>E##>yyyy>mm.dd>hh.mm>(r004)>”010”).
*011 Error code register 2.
*012 Error code register 3.
*013 Error code register 4.
*014 Error code register 5 (Oldest error: “014”>E##>yyyy>mm.dd>hh.mm>(r004)>”014”).
015
Coin vault access 1: (Most recent access: “015”>yyyy>mm.dd>hh.mm>”015”).
016 Coin vault access 2: time stamp 2.
017
Coin vault access 3: time stamp 3.
018 Coin vault access 4: time stamp 4.
019 Coin vault access5: (Oldest access: “019”>yyyy>mm.dd>hh.mm>”019”).
Note: “(r004)” in error-log time stamp indicates that the value of the total hour counter register 004
shall be displayed in this position of the sequence.