LAUNCH KES-200 Ignition Waveform
D-2
4.
Battery cable
5.
Ground cable
6.
Object to be tested
7.
Oscilloscope cable
8.
Main cable
Select [1.VOLT] on the main menu of multimeter, and
the unit will enter the voltage-measuring mode. After
grounding the ground cable and connecting the probe
to the object to be tested
,
the user can measure the
voltage of CH1 in the measuring range of DC -120V
to +120V.
Display Format:
The display of voltage measuring mode is as shown
in Fig.3-03.
Fig.3-03
The measuring range of voltage is displayed on the
top of the screen: -120V ~ +120V. The voltage
measuring value is displayed on the center of the
screen. User can press [ESC] key to return to the
upper-level menu, or press [HELP] key to view help
information.
Current Measuring Mode
Select [2.CURRENT] on the main menu of multimeter,
the unit will enter the current-measuring mode. After
grounding the ground cable and connecting the probe
to the object to be tested
,
the user can measure the
current of CH2. The measuring range is: –0.4 ~ +0.4A.
Display Format:
The display of current-measuring mode is as shown in
Fig.3-04.
Fig.3-04
The measuring range of current is displayed on the
top of the screen: –0.4 ~ +0.4A..
The current-measuring value is displayed on the
center of the screen. User can press [ESC] key to
return to the upper-level menu, or press [HELP] key to
view help information.
Resistance Measuring Mode
Select [3.RESISTANCE] on the main menu of
multimeter, the unit will enter the resistance-measuring
mode. After grounding the ground cable and
connecting the probe to the object to be tested
,
the
user can measure the resistance of CH1. The
measuring range is: 0.0~40.0M
Ω
.
Display Format:
The display of resistance-measuring mode is as
shown in Fig.3-05.
Fig.3-05
The measuring range of resistance is displayed on the
top of the screen: 0.0~40.0M
Ω
.