- 4 -
MAIN SPECIFICATIONS OF THE INSTRUMENT
Indicator with 6-wire load cell input in DIN box (48x96x130 mm; drilling template 45x91 mm) for panel
front mounting. Front panel protection rating IP54 (IP65 front optional). 6-digit semi
−
alphanumeric
display, 14 mm, 7 segments; 8 indicator LEDs. 4
−
key membrane keypad with buzzer. Real-time
clock/calendar with buffer battery.
Two serial ports (RS485 and RS232) for connection to: PC/PLC up to 32 instruments (max 99 with
line repeaters) by ASCII Laumas or ModBus R.T.U. protocol, remote display, printer.
The instrument can be connected to a CLM serie intelligent junction box or to a multi-channel weight
transmitter.
BUFFER BATTERY
The instrument is equipped with an internal battery that allows to keep active the internal clock even
in the event of power failure.
At the first start and after long periods of inactivity, leave the instrument on for at least 12
hours to fully charge the battery.