38
Clock accuracy
Calendar
Printing system
Power failure
compensation
Operating
environment:
Dimension
Weight
Power consumption
Rating of AC adapter
Monthly accuracy
±
15sec. (at ordinary temperatures)
Year up to 2099. Automatically adjusted to leap years, 31-day months
and months with thirty or fewer days, and the days of the week.
Dot matrix imprint
Three years of cumulative power failure hours after the date of shipment.
Temperature: -5˚to 45˚C, +23˚ to 113˚F
Humidity: 20 to 80%, no condensation
The unit operates normally at temperatures of 5˚C or below, but the print
density, reaction of the liquid crystal display, and the number of prints
at power failure are inferior to those at normal temperature operation.
160(w) x 184(d) x 144(h) mm, 6.3"(w) x 7.2"(d) x 5.7"(h)
Approx. 1.5 kg. (2.0 kg with AC adapter)
120VAC
±
10%, 60Hz, 0.5A
I/P AC 120V/60Hz O/P AC 15.0V 1300mA
NOTICE: Use only the supplied AC adapter.