- 8 -

Color monitor  MVC-8151

call volume

call tone

number of rings

Figure 3. User menu

User menu allows to:

•  change the call tone,
•  change the call volume,
•  set the number of rings,
• 

change the code of the code lock.

• 

register electronic keys.

To make changes a tenant must activate User menu. The help of the person in the apartment 

is needed for this. To activate the User menu, perform the following steps:
• 

Establish a connection with the apartment (only from the subordinate entry panel).

• 

Press the button KEY in the panel and still pressing it ask the person in the apartment to 

press the LOCK button in the monitor five times.

• 

Activation of the function is signaled by short beep in the monitor’s and the external pa-
nel’s loudspeaker as well as by message [OPC] displayed temporarily on the external pa-
nel`s display.

• 

Finish the conversation.

•  Enter the apartment number, then press the KEY button and enter the code  of  the code  

lock.  The display will show the symbols defining the current status of individual settings.

In Figure 3 is shown the view of the display after switching on the User menu (view for the 
default parameter values).

Change of tone, call volume and number of rings

•  [1] The first sign on the display defines the call tone (0 ... 7). The call signal can be chan

-

ged by pressing the button marked with number [1].

•  [2] The second sign on the display defines volume of call signal (G – loud, N – incre

-

asing, C – quiet, U – moderate). The selection of an increasing signal is sensible when the 

number of call signals is higher than 1. The volume is controlled with button [2].

•  [3] The  third  sign  on  the  display  defines  the  number  of  rings (1-8) – decides how 

long the door entry handset rings. Number of signals is controlled with button [3].

Summary of Contents for MVC-8151

Page 1: ...COLOR MONITOR MVC 8151 for Laskomex digital video door entry systems...

Page 2: ...c keys RFID 6 Using the touch electronic keys iButton 6 The quick entry function 7 User menu for CD 2502 and CD 3100 digital door phones 7 Change of tone call volume and number of rings 8 Code change...

Page 3: ...e It is recommended to use KSAS0181500120 or SAPC15018EU power supplies Self repair of devices included in the door entry system is forbidden because this results in loss of warranty Nie nale y przyk...

Page 4: ...itor is signaled by the bell at the same time the caller s image will appear on the screen To make a call press the CONVERSATION button during the call or within 30 seconds after the call The talk tim...

Page 5: ...ton in the monitor In this case the selected volume is signaled by LED1 and LED2 LED1 loud LED2 quiet LED2 flashing call disabled Fast flashing LED1 or LED2 means that the line is busy Adjusting the c...

Page 6: ...Using electronic keys To use electronic keys they must be registered in the door phone memory in advance The keys are registered by the installer or user The door phone user can register the key using...

Page 7: ...prox 10 minutes from the time of activation Activation of the quick entry function Answer the call Unlock the entrance by pressing the LOCK button Press the CONVERSATION button in the loudspeaker will...

Page 8: ...isplayed temporarily on the external pa nel s display Finish the conversation Enter the apartment number then press the KEY button and enter the code of the code lock The display will show the symbols...

Page 9: ...isplay Apply the electronic key to the reader Message NEU means that the key has been stored in the memory with the assignment to the apartment If a previously registered key has been applied to the r...

Page 10: ...not pose a threat to them and is not exposed to accidental hit Do not install the monitor in front of a window or strong light source as this may make it dif ficult to observe the image on the monitor...

Page 11: ...bell DING DONG gong signal For this purpo se a standard bell switch NO should be connected to the terminals of the CN_BELL plug It should be noted that the switch terminals were not connected to elem...

Page 12: ...inking as many times as next digits of the programmed number number of hundreds tens and units A longer pause means moving to the next digit in the programmed number and a longer fla shing of the LED1...

Page 13: ...ation for coaxial cable 1 2 CN_BELL CN_BP 1 BELL doorbell 2 GND doorbell ground 1 GND ground 2 PORT porter line 3 NO gate drive control 4 NO gate drive control 1 2 1 4 CN_CAM 1 VC power supply for add...

Page 14: ...apartment number Then the electronic mo dule automatically establishes connection with the handset or monitor in which the procedu re was activated giving the installer the ability to check the device...

Page 15: ...be replaced for a moment by gong sound and then swit ched on again All signals are automatically turned down during the conversation Note Bell terminals BELL GND should not be connected to any other e...

Page 16: ...itor MVC 8151 10 Technical data and wiring diagram Power 15V DC 1A Recommended power supply KSAS0181500120 SAPC15018EU Screen diagonal 7 Protection degree IP30 Operating temperature 5 40 C Dimensions...

Page 17: ...S BELL GND CN_BELL CN PWR CN_BP CN_CAM2 CN_CD controller splitter power supply CVR 2 audio ground 12V door entry panel COMMAX MON1 MON4 to EC 2502 or EC 3100 video porter switchboard 230V MVC 8151 but...

Page 18: ...18 Color monitor MVC 8151...

Page 19: ...19 Color monitor MVC 8151...

Page 20: ...equipment such as local collection points shops places appointed by the manufacturer or commune waste collection units List of collecting units of used Laskomex equipment is available on www laskomex...

Reviews: