- 7 -

Color monitor MVC-8151

a)

b)

 
Figure 2. Using electronic keys: a) iButton touch keys, b) RFID proximity keys
 

The „quick entry” function 

The function is available in the door entry system with the main entrance and the subordi-
nate entrance (entrances).

The visitor must first call the chosen apartment by selecting its number in the panel at the 
main entrance, then he must repeat this operation at the entrance to the staircase. If the „qu

-

ick entry” function was activated after the first connection, then when you try to connect 
from the door phone at the entrance to the staircase, the door locking electric strike will be 

automatically released.
The function remains active for approx. 10 minutes from the time of activation.

Activation of the „quick entry” function:
• 

Answer the call.

• 

Unlock the entrance by pressing the LOCK button.

• 

Press the CONVERSATION button – in the loudspeaker will be heard short sounds with 
increasing altitude signaling the activation of the function.

• 

End the conversation by pressing the PREVIEW button.

•  Again pressing the CONVERSATION button before the call ends will disable the „qu

-

ick entry” function.

User menu (for CD-2502 and CD-3100 digital door phones) 

The User menu is a mechanism that allows users of digital door phones to change some pa-
rameters of the door phone work. The changes concern the selected apartment number (the 
premises where the menu was activated). The introduced changes are then permanently sto-
red in the door phone’s memory.

Thanks to this, each user can adjust the work of the door phone to his expectations.

Summary of Contents for MVC-8151

Page 1: ...COLOR MONITOR MVC 8151 for Laskomex digital video door entry systems...

Page 2: ...c keys RFID 6 Using the touch electronic keys iButton 6 The quick entry function 7 User menu for CD 2502 and CD 3100 digital door phones 7 Change of tone call volume and number of rings 8 Code change...

Page 3: ...e It is recommended to use KSAS0181500120 or SAPC15018EU power supplies Self repair of devices included in the door entry system is forbidden because this results in loss of warranty Nie nale y przyk...

Page 4: ...itor is signaled by the bell at the same time the caller s image will appear on the screen To make a call press the CONVERSATION button during the call or within 30 seconds after the call The talk tim...

Page 5: ...ton in the monitor In this case the selected volume is signaled by LED1 and LED2 LED1 loud LED2 quiet LED2 flashing call disabled Fast flashing LED1 or LED2 means that the line is busy Adjusting the c...

Page 6: ...Using electronic keys To use electronic keys they must be registered in the door phone memory in advance The keys are registered by the installer or user The door phone user can register the key using...

Page 7: ...prox 10 minutes from the time of activation Activation of the quick entry function Answer the call Unlock the entrance by pressing the LOCK button Press the CONVERSATION button in the loudspeaker will...

Page 8: ...isplayed temporarily on the external pa nel s display Finish the conversation Enter the apartment number then press the KEY button and enter the code of the code lock The display will show the symbols...

Page 9: ...isplay Apply the electronic key to the reader Message NEU means that the key has been stored in the memory with the assignment to the apartment If a previously registered key has been applied to the r...

Page 10: ...not pose a threat to them and is not exposed to accidental hit Do not install the monitor in front of a window or strong light source as this may make it dif ficult to observe the image on the monitor...

Page 11: ...bell DING DONG gong signal For this purpo se a standard bell switch NO should be connected to the terminals of the CN_BELL plug It should be noted that the switch terminals were not connected to elem...

Page 12: ...inking as many times as next digits of the programmed number number of hundreds tens and units A longer pause means moving to the next digit in the programmed number and a longer fla shing of the LED1...

Page 13: ...ation for coaxial cable 1 2 CN_BELL CN_BP 1 BELL doorbell 2 GND doorbell ground 1 GND ground 2 PORT porter line 3 NO gate drive control 4 NO gate drive control 1 2 1 4 CN_CAM 1 VC power supply for add...

Page 14: ...apartment number Then the electronic mo dule automatically establishes connection with the handset or monitor in which the procedu re was activated giving the installer the ability to check the device...

Page 15: ...be replaced for a moment by gong sound and then swit ched on again All signals are automatically turned down during the conversation Note Bell terminals BELL GND should not be connected to any other e...

Page 16: ...itor MVC 8151 10 Technical data and wiring diagram Power 15V DC 1A Recommended power supply KSAS0181500120 SAPC15018EU Screen diagonal 7 Protection degree IP30 Operating temperature 5 40 C Dimensions...

Page 17: ...S BELL GND CN_BELL CN PWR CN_BP CN_CAM2 CN_CD controller splitter power supply CVR 2 audio ground 12V door entry panel COMMAX MON1 MON4 to EC 2502 or EC 3100 video porter switchboard 230V MVC 8151 but...

Page 18: ...18 Color monitor MVC 8151...

Page 19: ...19 Color monitor MVC 8151...

Page 20: ...equipment such as local collection points shops places appointed by the manufacturer or commune waste collection units List of collecting units of used Laskomex equipment is available on www laskomex...

Reviews: