7.4 P-3 Installation procedure
7 PROGRAMMING OF ENTRY PHONE
ibEn
1
(U,H)
Switching on/off of electronic keys
Setting parameter value to ”1” permits using electronic keys iButton (Dallas).
ibAd
1
(U,H)
Registration of electronic keys by users
Setting parameter value to ”1” permits the users to register new electronic keys
from user‘s menu.
5Ybr
1
(U)
Signaling number of the gate, from which a call has been received
When a call from slave entrance is being received, the doorphone may signal acous-
tically entrance number, from which such a call is coming from. The number is
signaled with a short acoustic signal after each calling cycle.
Ent
1
(U)
Fast entrance
In order to enter an apartment in a building with the main entrance two entrances
protected by entry phone system should be passed. An occupant must activate
electro-switch twice - the first time at the main entrance and the second time at
the subordinate entrance (see page. 43).
nrbl
1
(H)
Mode with building numbering
Switches on the mode with the building numbering. The function will operate
properly if parameter nbl in U exchanges is above zero.
7.4
P-3 Installation procedure
3
SWITCH ON THE INSTALLATION PROCEDURE
0
C
The procedure facilitates the activation of an entry phone system. Starting pro-
cedure P3 enables the installing specialist to check the correctness of functioning
of uniphones mounted in apartments without any help of other persons. Activation
of CD-3100 was described in chapter 6.12, on page 26.
P-3-0
ON/OFF
- switching on/switching off of installation procedure
P-3-1
LLO
- low range of searched numbers
P-3-2
LHi
- high range of searched numbers
P-3-3
Searching for the picked up (incorrectly placed) receiver. When this pro-
cedure is started, searching for picked up (incorrectly placed) receivers begins. On
the display numbers of successively checked apartments are being indicated. When
uniphone with the picked up (incorrectly placed) receiver is found in one of such
33