Notes:
Page 1: ...Video door phone set Bastion Apus II...
Page 2: ...installation of video door phone 6 Block diagrams 7 Connection diagrams 8 5 Assembly and connecting elements of video door phone 9 Assembly and connection MVC 7002 monitor 9 Connection a second monito...
Page 3: ...fire The external panel should be installed in a place with low noise level Video door phone elements should be connected to an electrical installation when the feeder is disconnected from the power n...
Page 4: ...access keyboard with a calling button The panel is surface mounted and equipped with a door strike relay activated on pressing the monitor button Fig 2 BVC 6504 outdoor panel 4 Fig 1 Monitor MVC 7002...
Page 5: ...phone should only be used with door releases rated at 13 5V DC 1A max When choosing the door release take into account the mechanical design of the gate of the door it will be installed with and the o...
Page 6: ...esented in Figure 7 The maximum distance between the external panel and the monitor should not exceed 100 m To put down in the ground and outside the room it is necesarry to use the damp proof cables...
Page 7: ...KSAD 1350120W1EU KSAD 1350120W1EU KSAD 1500120W1EU or GP005E 150 100 b Description of clamps with connected electro catch 1 Push Down 2 Wires How to use clamps in external panel white WIDEO red AUDIO...
Page 8: ...04 is changed KSAD 1350120W1EU Electro catch KSAD 1500120W1EU lub GP005E 150 100 230V AC 15V DC 1 2A 230V AC 13 5V DC 1 2A masa audio video audio video NO VDC za 12V za GND PRZ VDC Vcc 230V AC 15V DC...
Page 9: ...g and connecting the additional monitor For connecting two MVC 7002 monitors to a single outdoor panel run a separate power supply J100 socket to the additional monitor and connect the two monitors Se...
Page 10: ...tches on the camera view if an additional monitor has been installed the camera view will display on both monitors To switch on voice communication press the button talk see Fig 1 In two monitor insta...
Page 11: ...2 enter your 4 digit administrator code you will hear 3 short sounds red LED is flashing you are now in programming mode 3 enter the location 01 to 40 31 40 are the latching code locations If a serie...
Page 12: ...r 2 short sounds LED is flashing 5 press 7 times you will hear 5 short sounds LED is off Operation lock with code 1 enter your 4 digit user code 2 The red LED is lit this means user code is correct do...
Page 13: ...ree of protection IP43 Angle of view vertical horizon 36 48 Power supply KSAD 1500120W1EU or GP005E 150 100 Input voltage 230V AC 230V AC Output voltage 15V DC 1 2A max 15V 1A Dimension 81x43x67 81x43...
Page 14: ...Notes...
Page 15: ...Notes...
Page 16: ...List of collecting units of used Laskomex equipment is available on www laskomex com pl website or telephone No 42 671 88 68 Product packing should be removed according to environment protection regul...