background image

- The door release can be activated at any time during the conversation by pressing
the button 

 on the monitor. The release continues while the button remains pressed.

- The camera view on the monitor can be switched on at any moment by pressing the
button 

 (view). Pressing the button again will switch the view to the next entrance,

and pressing the button yet again will switch off the camera view.
- sequential operation. To activate voice communication in the camera view mode,
press the button   (talk).
- The MVC-7002 monitor features controls for volume, brightness and colour saturation
adjustment (see Fig. 1).

ATTENTION!

The camera view is activated with a delay of approx. 2 seconds after pressing the
View/Talk button.

7. 

Programming mode in panel BVC-6504

Entering programming mode

1) press *, you will hear 2 short sounds
2)enter your 4 digit administrator code, you will hear 3 short sounds, red LED is flashing
you are now in programming mode
3) to exit programming mode press the * key.

Adding user codes

1)press *, you will hear 2 short sounds
2)enter your 4 digit administrator code, you will hear 3 short sounds, red LED is flashing
you are now in programming mode
3)enter the location 01 to 40 (31-40 are the latching code locations). If a series of bleeps
are heard at this point then the location has a code stored, you may proceed as this
is only a warning.
4)enter the desired 4 digit user code, if the code lock retunes immediately to the
programmiong mode base level then the code is not permitted as it already exits else
where in another locations, if the code is permitted then you will hear 3 short sounds
5)return to step 2 to enter more user codes or press the * key to exit programming
mode.

ATTENTION!

In default configuration is not programmed any user code.

 DELETING USER CODES

1)press *, you will hear 2 short sounds
2)enter your 4 digit administrator code, you will hear 3 short sounds, red LED is flashing
you are now in programming mode
3)enter user location (01-40), you will hear 3 short sounds
4)press button #, you will hear 3 short sounds
5)return to step 3 to delete more codes or press the * key to exit programming mode.

11

LASKOMEX PPUH, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

Summary of Contents for Bastion Apus II

Page 1: ...Video door phone set Bastion Apus II...

Page 2: ...installation of video door phone 6 Block diagrams 7 Connection diagrams 8 5 Assembly and connecting elements of video door phone 9 Assembly and connection MVC 7002 monitor 9 Connection a second monito...

Page 3: ...fire The external panel should be installed in a place with low noise level Video door phone elements should be connected to an electrical installation when the feeder is disconnected from the power n...

Page 4: ...access keyboard with a calling button The panel is surface mounted and equipped with a door strike relay activated on pressing the monitor button Fig 2 BVC 6504 outdoor panel 4 Fig 1 Monitor MVC 7002...

Page 5: ...phone should only be used with door releases rated at 13 5V DC 1A max When choosing the door release take into account the mechanical design of the gate of the door it will be installed with and the o...

Page 6: ...esented in Figure 7 The maximum distance between the external panel and the monitor should not exceed 100 m To put down in the ground and outside the room it is necesarry to use the damp proof cables...

Page 7: ...KSAD 1350120W1EU KSAD 1350120W1EU KSAD 1500120W1EU or GP005E 150 100 b Description of clamps with connected electro catch 1 Push Down 2 Wires How to use clamps in external panel white WIDEO red AUDIO...

Page 8: ...04 is changed KSAD 1350120W1EU Electro catch KSAD 1500120W1EU lub GP005E 150 100 230V AC 15V DC 1 2A 230V AC 13 5V DC 1 2A masa audio video audio video NO VDC za 12V za GND PRZ VDC Vcc 230V AC 15V DC...

Page 9: ...g and connecting the additional monitor For connecting two MVC 7002 monitors to a single outdoor panel run a separate power supply J100 socket to the additional monitor and connect the two monitors Se...

Page 10: ...tches on the camera view if an additional monitor has been installed the camera view will display on both monitors To switch on voice communication press the button talk see Fig 1 In two monitor insta...

Page 11: ...2 enter your 4 digit administrator code you will hear 3 short sounds red LED is flashing you are now in programming mode 3 enter the location 01 to 40 31 40 are the latching code locations If a serie...

Page 12: ...r 2 short sounds LED is flashing 5 press 7 times you will hear 5 short sounds LED is off Operation lock with code 1 enter your 4 digit user code 2 The red LED is lit this means user code is correct do...

Page 13: ...ree of protection IP43 Angle of view vertical horizon 36 48 Power supply KSAD 1500120W1EU or GP005E 150 100 Input voltage 230V AC 230V AC Output voltage 15V DC 1 2A max 15V 1A Dimension 81x43x67 81x43...

Page 14: ...Notes...

Page 15: ...Notes...

Page 16: ...List of collecting units of used Laskomex equipment is available on www laskomex com pl website or telephone No 42 671 88 68 Product packing should be removed according to environment protection regul...

Reviews: