If during operation of the stove fuel burns so fast that there is almost never flame in the burner (even it can

appears  the “

Er03

” alarm), it  is  because  the  air  supplied  by  the  extractor  is  excessive  for  the  amount  of

pellets that are loading.

In this case, we can do two things:

-

Decreasing the amount of supplied air with

negative steps

of the

fan

(

check

6.1.7

).

-

Increasing the fuel load with

positive steps

in

pellet calibration

(

check

6.1.6

).

Before  changing  the  fan  and  pellet  calibration, it  is  necessary  to  make  sure  everything  is

correct:  installation,  maintenance  and  cleaning,  etc. For  this  we  can  check  the  chapter

8-

ALARMS, MENSSAGES AND PROBLEMS

”.

It is preferable to change first the fan calibration, so the pellet load also modify the output of the

stove.

5. INSTALLATION

The installation of LASIAN Air Stoves must be only carried out by qualified staff,
following  the  manufacturer's  instructions and  in  accordance  with  all  standards
and  regulations  that  are  applicable. Otherwise,  the  manufacturer  is  not  liable  for
any accident.

5.1 CHOICE OF LOCATION

It is forbidden to install the stove outside (exposed to the atmospheric agents) or in wet areas,
as  well  as  in  bedrooms,  locations  with  bath  or  shower  and  in  places  where  there  is  another
heating unit if they do not have the suitable dimensions and devoid of an adequate airflow.

When we choose the location of the stove, we will try that the route until the flue gas duct connection were as short
as possible, and flue gas can be discharged easily (check paragraph “

5.4- DUCT OR CHIMMEY

”).

Since in both, the stove and in the flue gas ducts it can be reached high temperatures, you have to follow certain
rules and safety recommendations to prevent possible fires and dangerous situations, so to make the installation
check paragraph “

5.3- DOMESTIC FIRE PREVENTION

”.

To ensure the air supply for the combustion in the stove, and keep a suitable ambient conditions, it has to keep in
mind everything  with  reference  to  ventilation  which  is  explained  in  paragraph “

5.5- AIR  INTAKE  AND

VENTILATION.

We must also have a suitable power point near the stove (check paragraph “

5.6- ELECTRIC CONNECTION

”), so

that  the  installation  has finished,  the  power  cord that  comes  with  the stove can  be  connected  and  disconnected
easily.

To make easier the  loading of the pellet  and the access to the control panel, as well  as the maintenance  or any
intervention  in  the  stove, it  will  be  necessary  to  leave  a  minimum  distances  above  and  around  it. A  reference  to
follow might be the ones described in paragraph “

5.3.1 MINIMUM SAFETY DISTANCES

”, although at least on the

right side of stove, it would be convenient to leave a minimum distance of 400 mm. in order to access to the rear
side of the stove.

Installation and use of the product should be in accordance with the manufacturer's
instructions, obeying European, national and local regulations where the product is
installed.

5.2 UNPACKING

Unpack  the  product  carefully  so  it  does  not  get  damaged  or  scratched.  Remove  from  the  tank  of  the  stove  the
accessory bag (it contains the legs of the stove, the power cord, the remote control, for the models which take it
and the instructions manual) and from the combustion chamber possible pieces of polystyrene or cardboard used
to block the removable parts, etc.

Also keep out of reach of children parts of the packaging (plastic bags, polystyrene, etc.) that could be potentially
dangerous and dispose according to the existing laws.

Summary of Contents for AUDAX 6 KW

Page 1: ...LASIAN Heat Technology S L PELLET STOVE 6 8 10 12 KW USER AND INSTALLATION MANUAL...

Page 2: ...COD 83119L 01EN 09 2016 2...

Page 3: ...this manual carefully because it will furnish important instructions regarding the safe installation use and maintenance o Installation of Air LASIAN stoves must be carried out by qualified personnel...

Page 4: ...COD 83119L 01EN 09 2016 4 STOVES 6 8 10 12 KW 6 kW 8 kW 10 kW 12 kW...

Page 5: ...n its different models AUDAX 6 KW AUDAX 8 KW AUDAX 10 KW AUDAX 12 KW WE HEREBY DECLARE under our sole responsibility that the above mentioned products are manufactured in accordance with the following...

Page 6: ...OF THE DUCT 19 5 4 3 USE OF A TRADITIONAL TYPE CHIMNEY 20 5 4 4 USE OF EXTERNAL CHIMNEY 21 5 4 5 FLUE DUCT ENDING 21 5 5 VENTILATION AND FRESH AIR INTAKE 22 5 6 ELECTRICAL CONNECTION 23 6 INSTRUCTION...

Page 7: ...WITCH OFF OFF 36 8 PROBLEMS MESSAGES AND ALARMS 36 8 1 PROBLEMS 37 8 2 MESSAGES 37 8 3 ALARMS 38 9 CLEANING AND MAINTENANCE 40 9 1 MAINTENANCE TABLE 41 9 2 DISPOSAL OF ASHES 42 9 3 BRAZIER CLEANING BU...

Page 8: ...requires particular attention In some cases it can be used capital letters or increase the font size to draw attention to some paragraphs Text in italics is used to draw your attention to other parag...

Page 9: ...o these standards Use of appropriate gloves is advised when handling coated parts to avoid leaving traces that are difficult to remove in the first cleaning The assembly of the stove should be carried...

Page 10: ...ve respecting the distances so that it is always visible MODEL AUDAX 6 kW AUDAX 8 kW AUDAX 10 kW AUDAX 12 KW Nominal thermal output min max kW 3 5 6 4 3 9 8 2 3 7 10 4 3 8 12 Efficiency at nominal red...

Page 11: ...ed sawdust extracted from the remains of the production and processing of dried natural wood the compactness of the product is guaranteed over time by a natural substance contained in the wood the lig...

Page 12: ...eters and lengths are valid for use in boilers 4 2 WHAT DO YOU HAVE TO KNOW ABOUT THE PELLET A certified pellet under any of the two previous standards DIN plus EN plus A1 would be the best guarantee...

Page 13: ...NDING ON THE PELLET THAT HAS BEEN USED As we have already explained in the previous section is clear that when the fuel that we use in the stove is changed this behavior may be different and although...

Page 14: ...high temperatures you have to follow certain rules and safety recommendations to prevent possible fires and dangerous situations so to make the installation check paragraph 5 3 DOMESTIC FIRE PREVENTIO...

Page 15: ...tove and play an important role to prevent possible fires 5 4 1 GENERAL NOTES It is recommended to keep out of the heat source area at least at 1 5 meters all flammable or combustible items such as wo...

Page 16: ...separate the stove from the floor We will use for this a fire resistant material such us a Steel sheet marble or tiles Whatever type of protection is chosen it must be able to withstand without defor...

Page 17: ...of paragraph 5 4 2 CHOICE AND CALCULATION OF THE DUCT The inner section should be uniform preferably circular square or rectangular sections must have rounded edges with a radius of at least 20 mm re...

Page 18: ...COD 83119L 01EN 09 2016 18 Fig 5 3 Fig 5 4 Fig 5 5 Yes Yes Direction of cleaning Direction of cleaning Direction of cleaning Sealing plug...

Page 19: ...hs are counted from the T output of the stove and it is from there where it should be increased the diameter of the duct if it is necessary see fig 5 6 LIMITATIONS WITH 80 mm PIPE WITH DOUBLE WALLED 1...

Page 20: ...gly recommended that you have it checked by a professional chimneysweep to ensure that it is completely airtight The reason for this is that the smoke because it is slightly pressurized can infiltrate...

Page 21: ...not less than twice of the flue pipe section o It must prevent the penetration of rain snow or foreign matter o The cowl must be installed to ensure the adequate dispersion and dilution of the combust...

Page 22: ...jacent room to the place of the installation provided this air flows freely through permanent apertures that cannot be closed and communicate with the outside The adjacent room must not be used as a g...

Page 23: ...er cord first behind the stove and then into an electrical outlet on the wall The main switch located on the back wall will be activated only when the stove is lit otherwise it is advisable to remove...

Page 24: ...king Display D4 Room temperature and parameter values The push buttons have different functions depending on the screen we are in and depending on whether the keystroke is short Clic or long long keys...

Page 25: ...n we see in the display that is below the abbreviation of the name of parameter and in the display on top their value The parameters to visualise in order of appearance are tF Fumes temperature C tA R...

Page 26: ...ing We will interrupt the load when the pellet falls off steadily in the burner for which you just have to push any button Due to security reasons the load will be interrupted automatically after 300...

Page 27: ...ment will not appear or if it appears must remain at 0 in order not to interfere with the electronic board adjustment 6 1 7 COMBUSTION FAN CALIBRATION DEACTIVATED FROM FACTORY The pellet combustion an...

Page 28: ...peed depending on the working power of the stove at your disposal 6 2 2 SCHEDULE PROGRAMMING CRON This function allows the schedule programming of ignition shutdown the stove It is formed by two secti...

Page 29: ...ay Friday Saturday Sunday MF SS For the schedule of ON the segment turns on below in the display D2 1I Mo For the schedule of OFF the segment turns on in the upper side of the display D2 1I Mo For eve...

Page 30: ...the schedule of ignition push the button P3 to enter and the modification and the selected value hours and minutes will start to flicker Push the button P3 to switch from hours to minutes and vice ver...

Page 31: ...ext day of the week Tuesday in this case the schedule of ON at 00 00 Crono programming Monday ON 22 00 1I Mo 23 59 1I Mo OFF Crono programming Tuesday ON 00 00 1I Tu 07 00 1I Tu OFF 6 2 3 TIME AND DAT...

Page 32: ...is to enter to the SAT parameters that are reserved to the Technical Assistance Service The access is protected by a password 7 USE AND WORKING OF THE STOVE 7 1 ADVICE AND WARNING Do not use the stove...

Page 33: ...at case the manufacturer will be exempt from criminal or civil liability The stove experiences changes of expansion and contraction during the phases of heating and cooling so it is completely normal...

Page 34: ...on the stove push the button for some seconds until you hear a whistle and it will appear on the lower right side the working power that has been selected see the section 6 1 2 Screen during the star...

Page 35: ...f the stove when the electronic board detects that is already burning During this stage the user can modify manually the power of working and the stove modulates the working power in function of the s...

Page 36: ...can start by different reasons If we force a switch off with the push button ON OFF When the stove enters in standby mode When it appears any message of error When the stove is in ignition recovery Du...

Page 37: ...e voltage in the plug see if the rear switch is on maybe the rear fuse is burnt out In days of strong wind or adverse weather conditions it is possible that the stove combustion is not good due to the...

Page 38: ...fumes temperature There is little pellet in the hopper A cave in the hopper has been produced and the pellet do not arrive to the load auger The load auger has been blocked or and the load motor does...

Page 39: ...gnition resistance and or the connection cable are damaged Empty and clean the burner reset the alarm and try another start up Check the conditions and quality of pellet If it does not start up after...

Page 40: ...to turn off the stove for some seconds pushing the back switch If after have followed every single step of how to reset the alarms and you do not get to reset the stove or if every time you try to st...

Page 41: ...CLEANING USER check paragraph 9 8 X T CONNECTION CLEANING USER check paragraph 9 7 X COMBUSTION CHAMBER CLEANING PROFFESIONAL OR AUTHORIZED TAS check paragraph 9 5 X FUEL HOPPER CLEANING USER check pa...

Page 42: ...event the overflow of ashes To take out the ash pan introduce the two fingers into the holes see Fig 9 1 pull it upwards and then outwards see Fig 9 2 Ashes must be placed in a metal container with a...

Page 43: ...cold and it would be desirable to do before every start or at least once a day To perform this cleaning we have on the front of the stove one or two knobs depending on the stove model Moving them bac...

Page 44: ...operation depends on the type of fuel used and the frequency of use To perform this cleaning it is advisable to contact a Technical Assistance Center 9 7 UNLOAD INSTALLATION CLEANING CHIMNEY It is rec...

Page 45: ...all particles accumulated at the bottom Never remove the protection grille which is inside the hopper 9 10 ANNUAL INSPECTION We call Annual Inspection to an extraordinary maintenance in which a comple...

Page 46: ...COD 83119L 01EN 09 2016 46 TAS INTERVENTIONS DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...

Page 47: ...COD 83119L 01EN 09 2016 47...

Page 48: ...unit and for manufacturing defects NOTE The manufacturer reserves the right to make product changes without notice always maintaining the technical and essential service characteristics to fulfill th...

Reviews: