background image

User Manual: V PRO-OEM 

Stand: 03/2010 

Page 5 of 8

Pattern 

0~255 

160/5=32pcs 

Horizontal rotation 

0~255 

slow to fast 

Vertical rotation 

0~255 

slow to fast 

Rotation about Z-axis 

0~255 

slow to fast 

10 

Horizontal movement 

0~255 

slow to fast 

11 

Vertical movement 

0~255 

slow to fast 

12 

Horizontal size 

0~255 

slow to fast 

13 

Vertical size 

0~255 

slow to fast 

14 

Hor. and vert. size 

0~255 

slow to fast 

15 

Drawing speed 

0~255 

slow to fast 

16 

Point draw 

0~255 

slow to fast 

17 

Scanspeed 

0~255 

slow to fast 

18 

Pattern size 

0~1 

Original size 

2~255 

Size (120=original) 

Maintenance / cleaning 

Always disconnect from mains before cleaning/opening the laser. Regularly clean the interior 
from dust, especially ensure operation of the fans. Use a sponge with alcohol, rather than 
wet cloth or other chemical liquid, to clean the mirrors. Be careful, even light scratches 
reduce the output power of the laser. Mirrors need cleaning, when a “halo” is noticeable 
around the beam, or an unusual high amount of diffuse light can be seen inside the device.

 

Technical specifications 

 

Modes:

 ILDA, DMX 512, auto, music active 

 

ILDA:

 25pin ILDA standard Sub-D shaped 25pin connector 

 

Galvos:

 50k scanspeed 

 

DMX 512:

 14 channels 

 

Patterns:

 160  

 

Scanangle:

 set to ca. 40° optical (60° max) 

 

Beam:

 ca. 3mm/1mrad 

 

Accessories:

 power cable, key switch, interlock plug, manual, safety cord 

 

The laser comes in a flightcase. 

 

Input voltage:

 AC 100~240V 50/60Hz 

 

Power consumption:

 450W 

 

Size:

 670 x 370 x 440 mm (W x D x H) 

 

Weight:

 30kg Laser, 

total:

 50kg 

(with 

flightcase)

 

 

Operating temperature:

 10°-35°C 

(below 20°C the power may be reduced) 

Change scanner 

1.

 

Unscrew UK M6 screws and disconnect signal 
cable. 

2.

 

Loosen M4 x 10 screw and remove galvo.  

3.

 

Insert galvo, reconnect and fix signal cable. 

4.

 

Rotate galvo to centre projection. Fix galvo. 

Adjustable mirror mounts 

1.

 

Loosen setscrews, then adjust with X/Y 
adjustable screws. Make sure beam is centred 
on scanner mirrors. 

2.

 

Adjust Z-screw simultaneously. 

3.

 

Tighten setscrews. 

Summary of Contents for V PRO-OEM

Page 1: ...V PRO OEM black User Manual OEM housing without laser sources Please read this manual carefully before use...

Page 2: ...switch it on immediately Condensation water may damage your device Leave the device switched off until it has reached room temperature The laser must only be used for shows Any operation has to be att...

Page 3: ...cribed in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc Keep surrounding dry...

Page 4: ...terface is connected to the laser the laser is automatically switched to ILDA mode Output is then controlled from a PC running software The laser uses pins 4 and 17 of the IDLA signal to detect the pr...

Page 5: ...ower of the laser Mirrors need cleaning when a halo is noticeable around the beam or an unusual high amount of diffuse light can be seen inside the device Technical specifications Modes ILDA DMX 512 a...

Page 6: ...ark or dim Lenses mirrors dirty Clean with alcohol Laser diode defective Laser diode Inquire Control board defective Control board 26 2A 2009LD 00 Configuration wrong mode Check configuration see para...

Page 7: ...solutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in thi...

Page 8: ...DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulation After installing the device an inspection and official approval is indispensable for the overall setup The in...