User Manual: V PRO-OEM
Stand: 03/2010
Page 3 of 8
eye damage. So these laser series models supplied with a key switch to prevent
unauthorized use, warning labels and aperture labels affixed to the laser.
Installation safety
Prior to installation and operation of the laser, the paths of the beams and effects should be
considered, particularly with respect to how they will reach the audience. If direct audience
scanning is desired, then the laser energy in the effects needs to be considered to decide if
the effects are safe for direct viewing. Always ensure, that the maximum permissible
exposure (MPE) is not exceeded in the area accesible to the public. So install the laser in
such a way, that minimum distances and heights ensure the MPE is never exceeded in the
public area.
OPERATING THE LASER
The operator has to make sure that laser radiation – also reflected laser radiation – higher
than the maximum permissible level is avoided by technical or organisational measures.
(Especially with respect to the MPE, see above.)
Make sure to use the correct voltage
If the device is used in a flying installation, the mounting brackets and an appropriate safety-
rope must be fixed.
In some countries, the operator must notify the accidence insurance and the authority for
industrial safety, before operating a laser. For more information, contact the relevant
authorities.
Please consider that unauthorized modifications on the device are strictly forbidden due to
safety reasons!
If this device will be operated in any way differently than described in this manual, the
product may suffer damages and the guarantee becomes void. Furthermore, any other
operation may lead to dangers like short-circuit, burns, electric shock, etc.
Keep surrounding dry and clean. T
his unit should be keep dry, do not use in the rain or
damp and dusty environment. Projector should be put in a water-proof housing when
operated outside.
Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog
fluid condenses in the housing (if so rearrange hazer and/or laser position).
Operating temperature is 10~35
°C
. In a new installation, check after some 15-30 minutes
whether the outlet air gets too warm. Regularly check the inside for dust deposits, especially
around the fans. Let laser cool off 10minutes after 2 hours of operation,to ensure maximum
lifetime for the diode.
Distance between laser aperture and projection screen should be not less than 1 meter.
Do not turn device on and immediately off again frequently.
Do not look into the laser beam directly, especially not with optical instruments.
Do not touch the device with wet hands.
When the laser diode becomes dim or broken, please contact your dealer timely.
When returning laser to dealer/manufacturer always use original packaging.
Maintenance should be performed every 15-day period. See “cleaning” further down.
Using the laser
Make sure the correct voltage is used. Connect mains. Connect an emergency switch to the
9-pin connector on the backside (pins 1, 2). If you do not wish to connect an emergency
switch, connect the 9-pin plug. Depending on the mode selected (see below), laser light
should come out of the opening on the front panel – be careful.
Control panel
3/4
DMX In/Out
5
Remotelock:
connect emergency switch. If no