background image

User Manual: Pro-3500RGB 

Stand: 11/2008 

Page 4 of 10 

In some countries, the operator must notify the accidence insurance and the authority for 
industrial safety, before operating a laser. For more information, contact the relevant 
authorities. 
Please consider that unauthorized modifications on the device are strictly forbidden due to 
safety reasons! 
If this device will be operated in any way differently than described in this manual, the 
product may suffer damages and the guarantee becomes void. Furthermore, any other 
operation may lead to dangers like short-circuit, burns, electric shock, etc. 
Keep surrounding dry and clean. T

his unit should be keep dry, do not use in the rain or 

damp and dusty environment. Projector should be put in a water-proof housing when 
operated outside.  
Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog 
fluid condenses in the housing (if so rearrange hazer and/or laser position). 
Operating temperature is 10~35

°C

. In a new installation, check after some 15-30 minutes 

whether the outlet air gets too warm. Regularly check the inside for dust deposits, especially 
around the fans. Let laser cool off 10minutes after 2 hours of operation,to ensure maximum 
lifetime for the diode. 
Distance between laser aperture and projection screen should be not less than 1 meter. 
Do not turn device on and immediately off again frequently. 
Do not look into the laser beam directly, especially not with optical instruments. 

Do not touch the device with wet hands. 

When the laser diode becomes dim or broken, please contact your dealer timely. 
When returning laser to dealer/manufacturer always use original packaging.

 

Maintenance should be performed every 15-day period. See “cleaning” further down. 

Using the laser 

Caution – use of controls or adjustments or performance of procedures 
other than those specified herein may result in hazardous radiation 
exposure. 

Make sure the correct voltage is used. Connect mains. Connect an emergency switch 
to the 9-pin connector on the backside (pins 1, 2). If you do not wish to connect an 
emergency switch, connect the 9-pin plug. Depending on the mode selected (see 
below), laser light should come out of the opening on the front panel – be careful. 

Control panel 

 

Control panel 

 

MODE: 

select mode, or go up in menu

 

 

ENTER: 

confirm changes, or go down in menu

 

 

UP/ DOWN: 

change DMX address

 

3/4 

DMX In/Out  

Remotelock:

 connect emergency switch. If no 

emergency switch is connected use the 9 pin plug 
supplied. 
 

Security switch:

 Laser on/off 

ILDA connector

 in/out

 

 

Power switch:

 power on/off 

Power:

 connect to mains. 

Summary of Contents for Pro-3500RGB

Page 1: ...Pro 3500RGB User Manual Please read this manual carefully before use...

Page 2: ...ode 5 DMX mode 5 Maintenance cleaning 6 Technical specifications 7 Change scanner 7 Adjustable mirror mounts 7 Troubleshooting 8 ILDA signal 8 Technical diagram 9 Please note 9 EU declaration of confo...

Page 3: ...s affixed to the laser Installation safety Prior to installation and operation of the laser the paths of the beams and effects should be considered particularly with respect to how they will reach the...

Page 4: ...peration to ensure maximum lifetime for the diode Distance between laser aperture and projection screen should be not less than 1 meter Do not turn device on and immediately off again frequently Do no...

Page 5: ...Further information can be found in the software manual DMX mode Channel DMX512 value Function 1 Red 0 255 0 100 Dimmer 2 Green 0 255 0 100 Dimmer 3 Blue 0 255 0 100 Dimmer 0 25 Original colour 26 51...

Page 6: ...terior from dust especially ensure operation of the fans Use a sponge with alcohol rather than wet cloth or other chemical liquid to clean the mirrors Be careful even light scratches reduce the output...

Page 7: ...mption 450W Size 670 x 370 x 440 mm W x D x H Weight 30kg Laser total 50kg with flightcase Operating temperature 10 35 C below 20 C the power may be reduced Change scanner 1 Unscrew UK M6 screws and d...

Page 8: ...2A 2009LD 00 Laser dark or dim Configuration wrong mode Check configuration see paragraph control panel Configuration wrong mode Check configuration see paragraph control panel Control board defectiv...

Page 9: ...absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in t...

Page 10: ...s regulations DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulation After installing the device an inspection and official approval is indispensable for the overal...

Reviews: