background image

User Manual: Pro-3500RGB 

Stand: 11/2008 

Page 3 of 10 

SAFETY INSTRUCTIONS  

If the device has been exposed to great temperature changes, do not switch it on 
immediately. Condensation water may damage your device. Leave the device 
switched off until it has reached room temperature. 
The laser must only be used for shows. Any operation has to be attended and 
supervised by a skilled and well-trained operator.   
Never leave this device running unattended and keep it away from children and 
unauthorized persons. 
Keep away from heaters and other heat sources. In order to safeguard sufficient 
ventilation, leave 50 cm of free space around the device. 
Never direct the laser beam to people or animals. 
CAUTION LASER DIODE: If you open the device for cleaning, always disconnect from 
mains! 

-

HEALTH HAZARD! Never look directly into the light source, as 

sensitive persons may suffer an epileptic shock!

 

These lasers are considered a definite eye hazard, 
particularly at the higher power levels, which WILL cause 
eye damage. So these laser series models supplied with a 
key switch to prevent unauthorized use, warning labels 
and aperture labels affixed to the laser. 

Installation safety 

Prior to installation and operation of the laser, the paths of the 
beams and effects should be considered, particularly with respect to how they will reach the 
audience. If direct audience scanning is desired, then the laser energy in the effects needs to 
be considered to decide if the effects are safe for direct viewing. Always ensure, that the 
maximum permissible exposure (MPE) is not exceeded in the area accesible to the public. So 
install the laser in such a way, that minimum distances and heights ensure the MPE is never 
exceeded in the public area. 

Warning labels on the device 

Laser radiation 

Read manual  

 

before use 

Avoid exposure 

Operation by qualified 

To the beam 

personal only 

Laser class 4 

Never direct laser  

 

Beam at people 

Caution of radiation 

Never look directly  

If cover is removed 

into beam  

 
Indoor use only 

At front opening:  

Avoid exposure – laser radiation is emmited. 

OPERATING THE LASER 

The operator has to make sure that laser radiation – also reflected laser radiation – higher 
than the maximum permissible level is avoided by technical or organisational measures. 
(Especially with respect to the MPE, see above.) 
Make sure to use the correct voltage 
If the device is used in a flying installation, the mounting brackets and an appropriate safety-
rope must be fixed. 

Summary of Contents for Pro-3500RGB

Page 1: ...Pro 3500RGB User Manual Please read this manual carefully before use...

Page 2: ...ode 5 DMX mode 5 Maintenance cleaning 6 Technical specifications 7 Change scanner 7 Adjustable mirror mounts 7 Troubleshooting 8 ILDA signal 8 Technical diagram 9 Please note 9 EU declaration of confo...

Page 3: ...s affixed to the laser Installation safety Prior to installation and operation of the laser the paths of the beams and effects should be considered particularly with respect to how they will reach the...

Page 4: ...peration to ensure maximum lifetime for the diode Distance between laser aperture and projection screen should be not less than 1 meter Do not turn device on and immediately off again frequently Do no...

Page 5: ...Further information can be found in the software manual DMX mode Channel DMX512 value Function 1 Red 0 255 0 100 Dimmer 2 Green 0 255 0 100 Dimmer 3 Blue 0 255 0 100 Dimmer 0 25 Original colour 26 51...

Page 6: ...terior from dust especially ensure operation of the fans Use a sponge with alcohol rather than wet cloth or other chemical liquid to clean the mirrors Be careful even light scratches reduce the output...

Page 7: ...mption 450W Size 670 x 370 x 440 mm W x D x H Weight 30kg Laser total 50kg with flightcase Operating temperature 10 35 C below 20 C the power may be reduced Change scanner 1 Unscrew UK M6 screws and d...

Page 8: ...2A 2009LD 00 Laser dark or dim Configuration wrong mode Check configuration see paragraph control panel Configuration wrong mode Check configuration see paragraph control panel Control board defectiv...

Page 9: ...absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in t...

Page 10: ...s regulations DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulation After installing the device an inspection and official approval is indispensable for the overal...

Reviews: