Specification  

 

Model Reference# 

LP-209 

Components 

Laser projector×1 
Power cable×1 
DMX512 cable×1 
Interlock 9pin plug×1 
Laser key×2 

Using voltage

 

AC 110V~230V

50/60Hz 

Voltage of input signal 

-10V ~ +10V 

Control Mode 

Auto/AUDIO/DMX/ILDA(optional) 

DMX channel 

12 

Scanning system 

20KPPS 

Lasers&Power

 

Green laser : 532nm/ 35~50mW 
Red laser : 650nm/140-150mW 

Operating temperature 

10°

 

~

 

40

°

 

Dimension(mm) 

280(L)×200(W)×150(H) 

Weight(kg) 

Safety fuse 

250V / F2A Φ5×20mm 

 

 

ATTENTION&MAINTENANCE 

1.

 

Do not disconnect the device without professional instruction 

2.

 

Keep surrounding dry and clean. T

his unit should be keep dry, do not use in 

the rain or dank and dusty environment. Projector should be covered with 
water-proof when operate at outside.  

3.

 

Keep surrounding temperature at15~30 ,Remain 10minutes for equipment 

cooling after 2 hours continuously work, or laser expected time will be 
reduced. 

4.

 

Distance between lasing aperture and projected item should not be less than 1 

meter. 

5.

 

Do not turn device on/off frequently to avoid broken. 

6.

 

Do not look into the laser beam directly, or view laser beam directly with 

optical instruments. 

7.

 

Do not touch the device with wet hands. 

8.

 

Turn off the power before installation and maintenance. 

9.

 

When the laser diode became dim or broken, please contact the dealer timely. 

10.

 

To use the original package when transport again and to avoid shake.

 

Summary of Contents for CS-200RGY

Page 1: ...CS 200RGY USER MANUAL Please read this manual carefully before use ...

Page 2: ...R MANUAL Laserworld CS 200RGY Date 01 2008 Page 2 of 11 Checking Parts Please check if the following parts are included 1 x CS 200RGY Laser 1 x Power cable 1 x DMX cable 1 x Interlock plug 1 x User manual ...

Page 3: ...is only allowed if it is controlled by a skilled and well trained operator Never leave this device running unattended and keep it away from children and unauthorized persons 2 Keep away from heaters and other heating sources In order to safeguard sufficient ventilation leave 50 cm of free space around the device 3 Never direct the laser beam to people or animals 4 CAUTION LASER DIODE Never unscrew...

Page 4: ...at the device will serve you for a long time without defects 10 In some countries the operator must notify the accidence insurance and the authority for industrial safety before operating a laser For more information contact the relevant authorities 11 Please consider that unauthorized modifications on the device are forbidden due to safety reasons 12 If this device will be operated in any way dif...

Page 5: ...0 L 200 W 150 H Weight kg 3 Safety fuse 250V F2A Φ5 20mm ATTENTION MAINTENANCE 1 Do not disconnect the device without professional instruction 2 Keep surrounding dry and clean This unit should be keep dry do not use in the rain or dank and dusty environment Projector should be covered with water proof when operate at outside 3 Keep surrounding temperature at15 30 Remain 10minutes for equipment coo...

Page 6: ...arly at the higher power levels which WILL cause eye damage So these laser series models supplied with a key switch to prevent unauthorized use warning labels and aperture labels affixed to the laser Installation safety Prior to installation and operation of the laser the paths of the beams and effects should be considered particularly with respect to how they will touch the audience If direct aud...

Page 7: ... Animal reference to DIP switch as below C DMX Control Mode The first part is DIP address code reference follow this to choose the mode you need DIP switch Address 1 10 Pin 1 ON 0 OFF x ON or OFF Address code Calculate When the mode is DMX control x x x x x x x x x 1 1 2 4 8 16 32 64 128 512 DMX control when address is 1000 0000 01 this mean is 1 x 1 1 the same you must select DMXchannel 1 as the ...

Page 8: ... connector by using a flat cable All outputs are symmetrical and be used in 3 different configurations 1 symmetrical signal Outputs and are connected directly with the corresponding pins of the receiving unit For signal inversion the 2 lines just have to be crossed 2 Single ended Output will be grounded to 0V GND and the outputs and GND have to be connectd to the inputs of the receiving unit 3 Sin...

Page 9: ... 17 5 Red Coloroutput Red 6 Green Coloroutput Green 7 Blue Coloroutput Blue 8 12 n c Not used 13 Shutter 5V 14 X Scanneroutput 15 Y Scanneroutput 16 Intens Intensity Blanking 17 Interlock B Internally connected to 4 18 Red Coloroutput Red 19 Green Coloroutput Green 20 Blue Coloroutput Blue 21 24 n c Not used 25 GND Signal ground 26 n c not used IDC connector only Note maximum load 20mA for 5V ...

Page 10: ...al Vertical Roll 6 Vertical Rolling 128 255 Auto Vertical Roll Speed from 0 to 16 8 0 127 Manual Horizontal 7 Horizontal Rolling 128 255 Auto Horizontal Roll Speed from 0 to 16 8 0 127 Manual Rotation 128 191 Auto clockwise rotation Speed from 0 to 16 4 8 Rotation 192 255 Auto anti clockwise rotation Speed from 0 to 16 4 0 85 Auto from small to large speed from 0 to 18 5 86 170 Auto from large to ...

Page 11: ...dards DIN EN 60065 2002 Furthermore the device is verified in correspondence to the laser class regulations DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulation After installing the device an inspection and official approval is indispensable for the overall setup The inspection must follow the european guidelines EN 60825 1 and corresponding regulations for th...

Reviews: