MultiMeter Pocket XP
31
Subject to technical alterations. 17W46
The accuracy ratings specified for an ambient temperature of
18 ... 28°C, rel. humidity < 70% rH . All AC voltage and current
ranges are specified for 5% ... 100% of the measuring range.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=mumepocxp
Diode test
Test current/voltage ≤ 0.3 mA / ≤ 3.3 V
Continuity test
Test current ≤ 0.5 mA
Response threshold ≤ 50 Ohm
Polarity
Sign for negative polarity
LCD
0 … 3999
Fuse
10A / 600V, flink (5 x 20 mm)
500mA / 600V flink (5 x 20 mm)
Protection class
II, double insulation
Overvoltage
CAT III - 600V, CAT IV - 600V
Pollution degree
2
Operating conditions
Max. humidity 80% rH, no condensation up
to 31°C, at higher levels linear derating up to
50% rH / ≤ 40°C, max. altitude 2000 m above
sea level
Storage conditions
-20°C … 60°C, Max. humidity 80% rH
Radio module
operating data
Bluetooth LE 4.x interface
Frequency band: ISM band 2400–2483.5 MHz,
40 channels
Transmission power: max. 10 mW
Bandwidth: 2 MHz
Bit rate: 1 Mbit/s; Modulation: GFSK/FHSS
Power supply
2 x AAA 1.5 Volt batteries
Dimensions
67 x 120 x 47 mm
Weight
262 g