16
– The measuring device complies with electromagnetic compatibility
regulations and limit values in accordance with EMC-Directive
2014/30/EU
–
The measuring device complies with safety and electromagnetic
compatibility regulations and limit values in accordance with
Directive 2014/35/EU (Low Voltage Directive / LVD) and 2014/30/EU
(Electromagnetic Compatibility Directive / EMC).
–
Umarex GmbH & Co. KG hereby declares that the MultiMeter-
Compact complies with the essential requirements and other
provisions of the European Low Voltage Directive 2014/35/EU (LVD)
and the Electromagnetic Compatibility Directive 2014/30/EU.
The EU Declaration of Conformity can be found in its entirety
at the following address: http://laserliner.com/info?an=ADV
– Local operating restrictions – for example, in hospitals, aircraft,
petrol stations or in the vicinity of people with pacemakers –
may apply. Electronic devices can potentially cause hazards
or interference or be subject to hazards or interference.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning
agents, scouring agents and solvents. Remove the battery(ies)
before storing for longer periods. Store the device in a clean and
dry place.
Safety instructions
Dealing with electromagnetic radiation and electromagnetic
disruptions
Additional information on use
Observe the technical safety regulations for working on electrical
systems, especially: 1. Safely isolating from power supply, 2. Secu
-
ring to prevent system being switched on again, 3. Checking zero
potential, two-pole, 4. Earthing and shortcircuiting, 5. Securing
and covering adjacent live components.
– Disconnect the power supply to the electrical circuit before
measuring or checking the diodes, resistance or battery charge.
– Check that all high-voltage capacitors are discharged.
– When connecting to a voltage, always connect the black
measuring lead first before the red lead. Follow the reverse
procedure when disconnecting.
– Only the original measuring leads may be used. Their voltage,
category and ampere rated powers must match those of the
measuring device.
EN