18
EN
A1
A2
2.
1.
Preparing the calibration check
It is possible for you to check the calibration of the laser. To do this, position the device
midway between 2 walls, which must be at least 5 metres apart. Switch the unit on and
use the SensoLite to define the marking points. For optimum results, please use a tripod.
1.
Mark point
A1
on the wall. (Use spot mode.)
2.
Turn the device through 180° and mark point
A2
. You now have a horizontal
reference between points
A1
and
A2
.
z
x
y
3. Rotation mode:
A laser beam rotating around 360° with a speed
of up to 200 rpm.
Activate mode
on rotation laser
with SensoCommander
Change speed
on rotation laser
with SensoCommander
Activate mode
on rotation laser
with SensoCommander
4. Hand receiver mode:
Optimum reception quality by constantly high
speed of (maximum speed = 500 rpm).
Note referring to all modes:
The red LED lights up when the limit of a range
has been reached (e.g. maximum speed, biggest scan angle).
!
Summary of Contents for BeamControl-Master