PLMNL0252 REV. B Effective Date: 10/16/17
15
FiberCUT
®
HR Operation Manual
3.3 Electrical Grounding and Noise
The capacitive height sensing circuitry
contained in the FiberCUT
®
HR cutting
head measures small changes in electrical
capacitance between the tip and earth-
ground to determine tip-to-part standoff
distance. In order for this circuit to function
properly the part and the cutting head need
to be connected to a good earth ground.
Ideally the ground should be
established from a ground rod,
approximately 2 meters in length driven
into the ground located near the base
of the machine.
A large gauge (1.6mm diameter or
larger) ground wire should be run from
the ground rod to the part.
Run a separate wire from the ground
rod to the FiberCUT
®
HR grounding
lug. See
Figure 21
Electrical noise can create height sensing
issues. Large electric motors, arc welders
and other devices may be a source of
significant electrical noise. In order to
eliminate this noise, it may be necessary to
connect a ground wire to the chassis of any
such device near the process.
3.4 Control Box Mounting
The control box mounting pattern is
illustrated in
. Important things to
consider when mounting the control box:
Standard cable length is 8 meters
(25 feet).
Easy access for maintenance.
Mounting so debris from the process is
not directed at the control box.
Mounting in an area where there are no
water leaks or oils from hydraulic lines.
Figure 22