8
Manual de Instrucciones
/ Instruction Manual
Bomba de Aluminio W20507, W21107
Aluminium Hand Pump
BREAK DOWNS AND
REPARATIONS
THE CYLINDER DOES NOT AVANCE
-
Lack of oil in the tank ____
Check the oil and fill the tank.
-
Release valve is open ____
Close the release valve.
-
Load is too heavy ____
Do not attempt to lift more than ratted tonnage.
-
Couplers not fully inserted ____
Check couplers.
-
Air trapped in the system ____
Remove air from the system.
-
Admission ball valve failure ____
Clean the seat and replace the ball.
-
Closing ball valve failure ____
Clean the seat and replace the ball.
THE CYLINDER DOES NOT REACH WORKING PRESSURE
-
Relief valve no calibrated ____
Calibrate the valve.
-
Retention ball valve failure ____
Clean the seat and replace the ball.
-
Closing ball valve failure ____
Clean the seat and replace the ball.
-
Pressure seal damaged ____
Replace the seal.
-
Cylinder pressure seal damaged (see cylinder) ____
Replace the seal.
THE CYLINDER DOES NOT RETRACT
-
Too much oil in the tank ____
Check the level.
SINGLE ACTING SYSTEM WITH 1 CYLINDER
SINGLE ACTING SYSTEM WITH 2 CYLINDERS
Ensure that all the equipment and accessories are suitable