Instructions and Maintenance Sheets
Electric Test Pump “HEP0250”
WARRANTY
LARZEP, S.A.
guarantees its products against all design and manufacturing defects for two years from the date of
purchase. This guarantee does not include the ordinary wear of both metal and non‐metal parts, abuse, using the
equipment beyond its rated capacity and any wear or damage incurred as a result of using a hydraulic fluid which is
not recommended by
LARZEP, S.A.
Please note that if the equipment is disassembled or serviced by anyone other than an authorized service dealer or
by
LARZEP, S.A
., this guarantee is rendered null and void.
In the event of a warranty claim, return the equipment to
LARZEP, S.A
. or the authorized dealer which sold you the
hydraulic equipment.
LARZEP, S.A
. will repair or replace the faulty equipment, whichever is deemed most
appropriate.
LARZEP, S.A.
shall not be held liable for any consequential damages or losses, which may occur as a
result of faulty equipment.
BEFORE USING THE EQUIPMENT AND ESSENTIAL SAFETY REQUIREMENTS
‐
This Electric test pumps HEP0250 has been designed for pressurizing and testing hydraulic systems and heating
systems. The pump can work with clean water, water solutions, light oils and non‐aggressive liquids with PH
between 7 and 12 and a maximum viscosity of 1.5 mPa∙s.
‐
Read the instruction manual carefully and practise using the equipment before application.
‐
Always use protective goggles, shoes and gloves.
‐
All pumps are tested individually, are tough and very robust and therefore very safe.
‐
Do not modify the pump (welded parts, etc.).
‐
Use the handles on the pump for transporting the device. Do not use the hose or pipe.
‐
Never exceed maximum working pressure of the pump. Ensure that all the equipment and accessories are
suitable for the maximum working pressure.
‐
Never turn on the pump when the pump is not connected to the plant.
Do not pressurize the pump without being
connected to an item to be pressurized unless a blanking plug is fitted to the outlet port.
‐
Never tighten or loosen connections while they are under pressure.
‐
Check that there are no damages on the pump. If there are worn or damaged pieces, replace them immediately.
‐
Respect electrical safety requirements: any operation must be performed by qualified personnel, only when the
machine is disconnected from power. Replace any electrical components if damaged. Keep dry any electric part.
‐
Work always in a safe way. Respect general safety conditions.
Before starting operation, check that the
installation is correct, the operator position is safe and the working zone is out of bounds to all personnel.
‐
In all cases, the operator should have received adequate training regarding the handling of the device and logical
safety criteria associated with the movement of heavy loads.
TECHNICAL FEATURES
Dimensions
500 x 500 x 750 mm
Weight
66 kg
Working Pressure
250 bar
Flow Rate
13 l/min
Outlet Port
1/2” BSP Male
Hose
1/2” BSP Female – 1.500 mm
Tank
100 litres
Motor
400 V ~ 50 Hz Three‐phase
Power
7 kW – 2.800 rpm
Max. Work Temperature 65 °C