background image

 

 

 

Instructions and Maintenance Sheets 

Electric Test Pump “HEP0250”

 

 

Replace the seals at least every two years. 

Change  oil  after  50  working  hours  first  time,  and  then,  every  500  working  hours.

 

Use  mineral  oil  SAE30.  This 

maintenance timing can change with harder working conditions

 

TROUBLE SHOOTING 

 

 

Pump does not reach the desired pressure: check in order: suction filter, air in the pump, pressure valves, inlet 
connections, seals. 

 

Pressure  change  continuously:  check  the  presence  of  air  bubbles  in  the  circuit,  check  the  presence  of  dirt,  the 
filter, valves and seals. 

 

Pressure drop: Check dirty on filter and valves. Check the gaskets. 

 

Noisy  pump:  Check  air  suctions.  Clean  and  move  the  valve.  Clean  the  filter.  Check  water  temperature.  Check 
mechanical parts, particularly ball bearings. 

 

Water  with  oil:  Change  the  oil  and  look  for  damaged  gaskets  and  rings.  High  humidity  may  cause  this 
inconvenience.  

 

Water leaking from the head: Change damaged gaskets and rings. 

 

Oil leaks: replace oil gaskets. 

 

Motor  Hum:  Turn  off  the  motor  immediately  and  verify  if  the  pump  is  not  blocked.  Check  if  the  voltage  in  the 
electric net corresponds with the data label. Remember that long power cords may cause voltage losses. Verify 
voltage at the pump plug. 

 

Motor stops suddenly:  Thermic  protection  switched  off  the pump  for  too high  temperature.  Check  if  voltage  is 
correct. Wait 10 minutes to re‐start.

 

 

Motor  does  not  start:  Check  electrical  connections,  thermic  protection,  emergency  stop  switch  and  magneto 
switch on the machine. Check differential on the power line

 

 
 
 
 
 

ELECTRIC SCHEME 

 

 

 

 

The pump must always be handled and repaired by qualified personnel.

 

Summary of Contents for HEP0250

Page 1: ...V01 2019 INSTRUCTIONS MAINTENANCE SHEET ELECTRIC TEST PUMPS HEP0250 LARZEP S A Avenida Urtiaga 6 48269 Mallabia Spain Tel 34 943 171200 Fax 34 943 174166 e mail info larzep com www larzep com ...

Page 2: ...2 Instructions and Maintenance Sheets Electric Test Pump HEP0250 DECLARATION OF CONFORMITY ...

Page 3: ...ve goggles shoes and gloves All pumps are tested individually are tough and very robust and therefore very safe Do not modify the pump welded parts etc Use the handles on the pump for transporting the device Do not use the hose or pipe Never exceed maximum working pressure of the pump Ensure that all the equipment and accessories are suitable for the maximum working pressure Never turn on the pump...

Page 4: ...accessories must be fitted correctly and not damaged suction tube with nut and filter pressure gauge and hose for high pressure Always use protective goggles shoes and gloves 9 Verify that electrical requirements of the motor are according to the electric power supply in the plant Then connect the motor to the power line Check that the motor runs correctly Ensure good motor ventilation Check that ...

Page 5: ...ter temperature Check mechanical parts particularly ball bearings Water with oil Change the oil and look for damaged gaskets and rings High humidity may cause this inconvenience Water leaking from the head Change damaged gaskets and rings Oil leaks replace oil gaskets Motor Hum Turn off the motor immediately and verify if the pump is not blocked Check if the voltage in the electric net corresponds...

Reviews: