4. 

Additional clamps may  be  used,  if needed  to secure  power cable to piling. Prevent abrasion by  routing cable  to 
side of piling away from vessel access. Do not over tighten the clamp on the cable where it can cut or pinch the 
cable. 

 

Power Unit Installation 

 
Note:

 This fixture is suitable for installation  in  wet  locations. It is  not intended to be submerged or exposed to repeated 

direct wave action. 
 

1. 

Determine the mounting location of the Power Unit ensuring all underwater light cables reach the supply and are 
routed to prevent abrasion from vessels or other moving components. 

2. 

With provided stainless steel screws, attach power unit to suitable structure at least 1 foot above ground level with 
the high and low voltage cables pointing down. 

NOTE: 

Do not energize transformer until installation of system is 

complete. 

 

Electrical Connection  

 

Notes: 

 

Fixture may be switched with a timer, photo detector, or toggle switch prior to the receptacle.  

DO NOT connect power unit to a dimmer. 

 

Use approved outdoor (While in use) weatherproof receptacle cover to protect cord and outlet from weather while 
plugged in. 

 

Provide electrical service  according  to the  electric code for  your specific application  from a suitable ground  fault 
circuit interrupter (GFCI) receptacle. 

 

1. 

All  high  voltage  components  in  the  fixture  are  prewired  so  electrical  connection  only  needs  to  be  made  on  the 
secondary (24VDC low voltage) side of the power supply. 

NOTE:

 the power unit is rated for 110W max load. Do 

not connect more than 4 dock lights to this supply. 

2. 

Split low voltage cable back approximately 3 inches and strip conductors back 3/8 inch if not already done so. 

3. 

Insert low voltage cables into cable glands on the bottom of the power unit. Tighten cable glands until the cables 
are secure. 

4. 

Connect all red wires together by lifting orange levers on connector and inserting conductor so that bare metal is 
not exposed. Fold levers down once conductor is inserted. Check for secure connection. 

Complete the same procedure on black low voltage wires. Note: Low voltage cables must remain in the bottom of 
the power unit enclosure and must not be routed near high voltage splice. 

 

Operation 
 

An abrupt OFF/ON toggle  of  your switch allows the dock light to transition through various light output modes. Light  will 
cycle through all available colors within the first 20 seconds, (including white). A brief OFF/ON toggle will allow the user to 
select  any  discrete  color  during  the  cycle.  After  20  seconds  without  interruption,  the  light  will  continue  a  full  color  cycle 