29
Smart Illumination
NOTE:
This function may vary with models, please see actual Web interface for details.
1.
Click
Setup
>
Image
>
Image
and then click
Smart Illumination
.
2.
Select the correct IR control mode and set the parameters. The following table describes some
major parameters.
Parameter
Description
Lighting Type
Infrared
: The camera uses infrared light illumination.
NOTE:
When Control Mode is set to Manual, camera can set illumination level from
0~1000.
Control Mode
Global Mode
: The camera adjusts IR illumination and exposure to achieve
balanced image effects. Some areas might be overexposed if you select
this option. This option is recommended if monitored range and image
brightness are your first priority.
Overexposure Restrain
: The camera adjusts IR illumination and exposure
to avoid regional overexposure. Some areas might be dark if you select this
option. This option is recommended if clarity of the central part of the image
and overexposure control are your first priority.
Manual
: This mode allows you to manually control the intensity of IR
illumination.
Illumination
Level
Set the intensity level of the IR light. The greater the value, the higher the intensity. 0
means that the IR light is turned off.
NOTE:
You can set this parameter only when
Control Mode
is set to
Manual
.
3.
To restore the default settings, click
Default
.