background image

EPLRL-50-16.4-HR-SWB

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

5

 of 

5

 

Adding Spring Tension 

5. Feed the end of the cable through the cable guide and pull the cable out the required length.
6. Repeat steps 3 to 5, if necessary, to add tension. To decrease tension, rotate drum and cable counter-clockwise.

Power Connections 

1. Provide power source with over-current protection to prevent overheating of the reel and cable.
2. Reels are supplied with 6’ feeder cords. Those cords are the same cable as is supplied on the spool. They are factory sealed 

with explosion proof potting compound and supplied with a watertight strain relief. If a conduit connection is required, the strain 
relief must be removed and conduit connections made.

OPERATION 

1. Do not exceed the voltage or amperage for the cable. Overheating, fire, damage to equipment or personal injury could result.
2. Do not allow cable to retract without restraining the retraction speed.
3. Operate the reel within the cable size and length and spring tensioning limits for which it was intended.
4. Keep two wraps of cable on the reel at maximum extension to avoid excessive tension on the cable and to prevent pullout of 

cable from entrance watertight.

MAINTENANCE 

There are no serviceable parts inside the fixture. However, it is good practice to routinely clean and check the 

fixture for proper function. 

Disconnect power running to the 

unit

 and be sure the fixture is cool to the touch.

Use a non-abrasive cleaning solution to clean the 

fixture

.

USE AND CARE

Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. 

Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of 

children when not in use. Inspect for good working condition prior to storage and before re-use.

 

 

REPLACEMENT PARTS

The 

EPLRL-50-16.4-HR-SWB

 is designed to provide years of reliable performance. Should the need for replacement 

parts arise, please contact Larson Electronics. 

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. 

SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 1-800-369-6671 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

Summary of Contents for EPLRL-50-16.4-HR-SWB

Page 1: ...D MAINTENANCE PRODUCT MUST BE CONNECTED TO A WIRING SYSTEM WITH AN EQUIPMENT GROUNDING CONDUCTOR TO AVOID EXPLOSION MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS ATMOSPHERE DO NOT OPERATE IN AMBIENT TEMPERATURES ABOVE THOSE INDICATED ON THE PRODUCT NAMEPLATE DO NOT OPERATE IF THE LENS CORD SEALS HOUSING R...

Page 2: ...herproofing all connections if installed in a location where water may come in contact with the unit Ensure the unit is properly grounded and that wiring is done according to all local and national electrical building codes INSTALLATION Stretch Applications The cable is suspended without any intermediate support Stretch reels generally require a line pull equal to two times the weight of the cable...

Page 3: ...suitable for applications requiring continuous rotation 3 A pivot base is required carousel or loop track applications 4 When a pivot base is used the reel must be mounted horizontally ceiling or floor mounted 5 The roller guide should be mounted so the cable will travel perpendicular to the axis of rotation This will guard against the cable twisting and ensure effective swivel action from the piv...

Page 4: ...process Always maintain two full cable wraps on drum at maximum cable extension size cable accordingly 1 The EXPCRL reels come with pre tension from the factory Some adjustments may be required to meet specific application requirements 2 To assure that the cable will retract properly and operate under the correct tension for intended application the reel should be tested Securely mount reel before...

Page 5: ...maximum extension to avoid excessive tension on the cable and to prevent pullout of cable from entrance watertight MAINTENANCE There are no serviceable parts inside the fixture However it is good practice to routinely clean and check the fixture for proper function Disconnect power running to the unit and be sure the fixture is cool to the touch Use a non abrasive cleaning solution to clean the fi...

Reviews: