Description

Pump feed air pressure regulator
Pump feed air manometer
Air closing cock
Pump feed air inlet
Pump fastening and supporting bracket
Material inlet fitting
Material outlet filling

e

MADE   IN   ITALY

WWW.LARIUS.EU

MODEL

SERIAL NUMBER

YEAR

OF COSTRUCTION

DesCrIptION 
OF tHe eQUIpMeNt

The 

LarIUs 4

 pump is a double diahragm pneuma-

tic pump to be used for transfer of low and medium 
viscosity fluids.
It is essentially composed of two chambers which are 
placed on suctio and on delivery alternatively thanks to 
the action of two membranes in teflon connected to a 
shaft in reciprocating traverse motion. The reciprocating 
motion is obtained through a proper compressed air 
driver reversal device (pilot valve).

traNspOrt aND  UNpaCKING

•   The packed parts should be handled as indicated in the 

symbols and markings on the outside of the packing.

•  Before installing the equipment, ensure that the area to 

be used is large enough for such purposes, is properly 
lit and has a clean, smooth floor surface.

•   The user is responsible for the operations of unloading 

and handling and should use the maximum care so as 
not to damage the individual parts or injure anyone.

 

To perform the unloading operation, use only qualified 
and trained personnel 

(truck and crane operators, etc.)

 

and also suitable hoisting equipment for the weight of 
the installation or its parts. 

 

 Follow carefully all the safety rules.

 

The personnel must be equipped with the necessary 
safety clothing.

•  

The manufacturer will not be responsible for the unlo-
ading operations and transport to the workplace of the 
machine.

•   Check the packing is undamaged on receipt of the equi

-

pment. Unpack the machine and verify if there has been 
any damage due to transportation.

 

In case of damage, call immediately 

LarIUs

  and  the   

Shipping Agent. All the notices about possible damage 

IDeNtIFICatION

D

For communications with LARIUS, always refer to the machine 
model contained on the identification plate.

Summary of Contents for 4

Page 1: ...www larius eu Ediz 002 06 2019 II 2 G c IIB T4 Larius 4 Transfer INSTRUCTION MANUAL ...

Page 2: ...ils mentioned in this manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconveniences that may arise due to the incorrect translation of the instructions contained within the original manual in Italian ...

Page 3: ...HE REED AIR p 10 POSITIONING DIAGRAM p 11 TUNING p 11 WORKING p 11 EMERGENCY STOP p 11 PROBLEMS AND SOLUTION p 12 spare parts EXPLODED PNEUMATIC MOTOR UNIT VIEW p 14 MARKINGS p 16 SAFETY INSTRUCTIONS FOR INSTALLATION IN HAZARDOUS AREAS p 17 EXAMPLE OF INSTALLATION p 10 WE ADVISE THE USE OF THIS EQUIPMENT ONLY BY PROFESSIONAL OPERATORS ONLY USE THIS MACHINE FOR USAGE SPECIFICALLY MENTIONED IN THIS ...

Page 4: ...Edit 002 06 2019 www larius eu LARIUS 4 4 White page intentionally ...

Page 5: ...dicates wound and finger squashing risk due to movable parts in the equipment Tenersi lontano dalle parti in movimento Do not use the equipment without the proper protection Before any inspection or maintenance of the equipment carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion...

Page 6: ...tegral with the exchanger shaft creates a vacuum and intakes the fluid Oncethestrokehasbeencompleted thepneumaticexchangerdivertsthe compressed air behind the opposing diaphragm and the cycle is reversed TECHNICAL DATA B N B The pump is supplied with a bayonet connection Parts of the pump in contact with the material In the standard model in Aluminium code 8000 the parts are made of AluminiumAISI1...

Page 7: ...Edit 002 06 2019 www larius eu LARIUS 4 7 320 390 N Code 8300 8301 A Alluminium Stainless steel Pump LARIUS OUT IN 163 170 A 10 103 206 215 ...

Page 8: ... the packing Before installing the equipment ensure that the area to be used is large enough for such purposes is properly lit and has a clean smooth floor surface The user is responsible for the operations of unloading and handling and should use the maximum care so as not to damage the individual parts or injure anyone To perform the unloading operation use only qualified and trained personnel t...

Page 9: ...HECK REGULARLY THE COMPONENTS OF THE SYSTEM REPLACE THE PARTS DAMAGED OR WORN Tighten and check all the fittings for connection between pump flexible hose and spray gun before using the equipment Always use the flexible hose supplied with standard kit THE USE OF ANY ACCESSORIES OR TOOLING OTHER THAN THOSE RECOMMENDED IN THIS MANUAL MAY CAUSE DAMAGE OR INJURE THE OPERATOR The fluid contained in the...

Page 10: ...manufacturer use of non original spare parts or parts that do not correspond to the specific model total or partial non compliance with the in structions provided condiTIONS OF GUARANTEE G INSTALLATION WASHING OF THE BRAND NEW EQUIPMENT TheLARIUS4pumphasbeentestedatourplant with light mineral oil left inside of the pumping elementi ad protection Before sucking the pro duct carry out a washing usin...

Page 11: ...e product chamber will be full Each time the delivery valve is open the pump will start again to work WARNING Avoidpumpidingbecauseitcouldda magethepneumaticsystemandthemembranes EMERGENCY STOP In the case of an emergency promptly close the air opening closing valve 1 blocking motor power H WORKING To avoid risks after stops keep the valve open and completely discharge the pump POSITIONING DIAGRAM...

Page 12: ...crease the feed hose diameter Clean Detach the product outfeed hose Power the pump at minimum pressure and check if the pump starts without the outfeed hose Checkthehoseandtheintakefilter Clean Replace the membrane Press the reset buttons located at the sides of the valve Add the product Check the suction pipe Remove and clean and or replace the balls and ball seats Check the air supply line Incre...

Page 13: ...Edit 002 06 2019 www larius eu LARIUS 4 13 J SPARE PARTS List of spare parts pag 14 ...

Page 14: ...2 23 22 23 22 21 24 21 24 21 24 21 20 13 16 40 39 42 6 4 5 7 5 6 7 3 2 40 39 37 38 15 12 41 11 10 9 8 2 5 6 7 5 6 7 30 31 32 35 34 33 36 29 27 26 18 19 1 17 15 14 41 11 10 9 8 4 EXPLODED PNEUMATIC MOTOR UNIT VIEW WARNING always indicate code and quantity for each part required ...

Page 15: ...ket Screw Ball valve Fitting Pressure regulator Fitting Elbow fitting Pressure gauge Bayonet attack Silencer Plug Washer Nipplo 1 Gas Internal membrane pressing disc Screw 1 2 16 2 4 4 4 2 2 2 1 1 5 1 2 4 1 1 1 1 5 5 5 4 1 2 2 8 1 1 1 1 1 1 1 1 1 2 2 2 8 1 2 16 2 4 4 4 2 2 2 1 1 5 1 2 4 1 1 1 1 5 5 5 4 1 2 2 8 1 1 1 1 1 1 1 1 1 2 2 2 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24...

Page 16: ...umps series 2 and 4 II 2 G c IIB T4 Tamb 10 C 50 C Tmax fluid 60 C Tech File LARIUS 2 4 ATEX 05 Group II surface Category 2 zone 1 Explosion hazardous environment with presence of gas fog and vapour Manufacturing safety c Class of temperature T5 Environment temperature Maximum fluid temperature Serial number xxxxx PROGRESSIVE year AA ...

Page 17: ...ble that a filter will be placed at the suction of the material to prevent solid parts entering the pump The pipes used to connect suction and delivery must be metallic or plastic with metallic braid or plastic with fabric braid with suitable earthing cable According to duties it is recommended the control of diaphragms and replacement The air feeling the pump needs to be filtered and origi nated ...

Page 18: ... double diaphragm pu mps series 2 and 4 to which this declaration relates complies with the following Directives Direttive 94 9 EC ATEX 3 X The conformity are under observance of the fol lowing standards or standards documents EN 1127 1 EN 13463 5 EN 13463 1 Marking II 2 G c IIB T4 Tamb 10 C 50 C Tmax fluido 60 C Tech File LARIUS 2 4 ATEX 05 Technical file c o INERIS 0080 Calolziocorte LC Signatur...

Page 19: ...Edit 002 06 2019 www larius eu LARIUS 4 19 White page intentionally ...

Page 20: ...Made in Italy 1969 www larius eu LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com ...