![Larius 4 Instruction Manual Download Page 6](http://html1.mh-extra.com/html/larius/4/4_instruction-manual_676414006.webp)
Edit. 002 - 06/2019
www.larius.eu
LARIUS 4
6
a
8 bar (115 psi)
2-8 bar (30-115 psi)
1/4" GAS (F)
40 l/min
1” GAS (M)
1” GAS (M)
190 l/min (6,7 cfm)
<75 dB (A)
9 kg
LarIUs 4
WOrKING prINCIpLe
pneumatic double membrane pumps for industrial pumping of
liquids and highly corrosive and aggressive acids.
Characterised by their high performance, high power and stur-
diness, which make them suitable for pumping liquids with high
viscosity, including in the presence of suspended solids. They
meet the working needs of the chemical, textile, food, ecologi-
cal, graphics, tanning, ceramics, electronics, galvanic, oil, paint,
biodiesel, urea pumping and other industries
The compressed air introduced by the pneumatic exchanger
behind one of the two diaphragms generates compression and
pushes the product into the delivery duct, at the same time, the
opposing diaphragm that is integral with the exchanger shaft
creates a vacuum and intakes the fluid.
Once the stroke has been completed, the pneumatic exchanger diverts the
compressed air behind the opposing diaphragm and the cycle is reversed.
teCHNICaL Data
B
*N.B.
The pump is supplied with a bayonet connection.
parts of the pump in contact with the material
In the standard model in Aluminium (code 8000) the parts are
made of:
Aluminium AISI 12 UNI 5076 - Teflon - Galvanized steel - Stainless
steel AISI 316 and AISI 303 - Teflon
In the Stainless steel model (code 8132) they are made of: Stain-
less steel AISI 316 and AISI 303 - Teflon
OTHER pARTS OF THE pUMp
pump body: ALUMINIUM
Supporting bracket: GALVANIZED STEEL
always observe these instructions care-
fully when evaluating the product com-
patibility and in case of disposal of some
parts of the pump no more usable, in order
to meet the environmental regulations on
recycling process.
MAXIMUM PRESSURE OF THE PRODUCT
PUMP FEED AIR PRESSURE
*FEED AIR INLET
MAXIMUM DELIVERY
MATERIAL INPUT
MATERIAL EXIT
MAXIMUM AIR CONSUMPTION
NOISE PRESSURE LEVEL
wEIgHT
Summary of Contents for 4
Page 1: ...www larius eu Ediz 002 06 2019 II 2 G c IIB T4 Larius 4 Transfer INSTRUCTION MANUAL ...
Page 4: ...Edit 002 06 2019 www larius eu LARIUS 4 4 White page intentionally ...
Page 13: ...Edit 002 06 2019 www larius eu LARIUS 4 13 J SPARE PARTS List of spare parts pag 14 ...
Page 19: ...Edit 002 06 2019 www larius eu LARIUS 4 19 White page intentionally ...