8: Setup Mode: Channel Configuration
XPress™ DR+ Industrial Device Server User Guide
59
Figure 8-2 Hostlist Option
Baud rate (9600) ?
I/F Mode (4C) ?
Flow (00) ?
Port No (10001)?
ConnectMode (25) ?
Send ‘+++’ in Modem Mode (?) ?
Auto increment source port (N) ?
Hostlist :
01. IP : 172.019.000.001 Port : 00023
02. IP : 172.019.000.002 Port : 03001
03. IP : 172.019.000.003 Port : 10001
Change Hostlist ? (N) ? Y
01. IP address : (172) .(019) .(000) .(001) Port : (23) ?
02. IP address : (172) .(019) .(000) .(002) Port : (3001) ?
03. IP address : (172) .(019) .(000) .(003) Port : (10001) ?
04. IP address : (000) .(000) .(000) .(000)
Hostlist :
01. IP : 172.019.000.001 Port : 00023
02. IP : 172.019.000.002 Port : 3001
03. IP : 172.019.000.003 Port : 10001
Change Hostlist ? (N) ? N
Hostlist Retrycounter (3) ?
Hostlist Retrytimeout (250) ?
DisConnMode (00) ?
FlushMode (00) ?
DisConnTime (00:00) ?:
SendChar 1 (00) ?
SendChar 2 (00) ? _
To enable the hostlist:
1. Enter a
Connect Mode
of 0x20 (
2
X), where X is any digit. The menu shows you a list of
current entries already defined in the product.
2. To delete, modify, or add an entry, select
Yes
. If you enter an IP address of
0.0.0.0
, that
entry and all others after it are deleted.
3. After completing the host list, repeat the previous step if necessary to edit the host list
again.
4. For
Retrycounter
, enter the number of times the Lantronix unit should try to make a
good network connection to a host list entry that it has successfully ARPed. The range is 1-
15, with the default set to
3
.
5. For
Retrytimeout
, enter the number of seconds the unit should wait before failing an
attempted connection. The time is stored as units of milliseconds in the range of
1-65535. The default setting is
250
.