5: Configuration Using Web Manager
XPress™ DR+ Industrial Device Server User Guide
45
Figure 5-7. UDP Connection Settings
Connect Protocol
Protocol
Select
UDP
from the drop-down menu.
Datagram Mode
Datagram Type
Configures the remote IP or network broadcast address and the
remote port. Enter
01
for directed or broadcast UDP. The default
setting is
00
.
Accept Incoming
Select
Yes
to accept incoming UDP datagrams.
Endpoint Configuration
Local Port
Enter the local port number.
Remote Port
Enter the port number of the remote device.
Remote Host
Enter the IP address of the remote device.
Use Broadcast
Check to broadcast the UDP datagram. Datagrams of type 01 can be
sent as a broadcast by enabling this option. The default is not to
Broadcast (unchecked).
Note:
Datagrams are sent as subnet-directed broadcasts.
Device Address Table
The table is enabled when
Datagram Type
is set to
FD
. Enter values
between
1
and
255
to identify the
Dev Addr
(device address) of units
on the local network of device servers.