8: Setup Mode: Channel Configuration
XPress™ DR+ Industrial Device Server User Guide
56
Connect Mode
Connect Mode defines how the unit makes a connection, and how it reacts to incoming
connections over the network.
ConnectMode (C0) ? _
Enter Connect Mode options in hexadecimal notation. The default setting is C0.
Note:
All bit positions in the table that are blank represent “don’t care” bits, for that
particular option, which can be set to either a 0 or 1 value.
Table 8-5 Connect Mode Options
Connect Mode Option
7
6
5
4
3
2
1
0
a) Incoming Connection
Never accept incoming
0
0
0
Accept with active Modem Control In
0
1
0
Always Accept
1
1
0
b) Response
Nothing (quiet)
0
Character response (C=connect, D=disconnect,
N=unreachable)
1
c) Active Startup
No active startup
0
0
0
0
With any character
0
0
0
1
With active Modem Control In
0
0
1
0
With a specific start character
0
0
1
1
Manual connection
0
1
0
0
Autostart
0
1
0
1
Hostlist
0
0
1
0
d) Datagram Type
Directed UDP
1
1
0
0
e) Modem Mode
No Echo
0
0
1
1
Data Echo & Modem Response (Numeric)
0
1
1
1
1
Data Echo & Modem Response (Verbose)
0
1
1
1
0