5: Configuration Using Web Manager
XPress™ DR+ Industrial Device Server User Guide
37
Retype Password
Re-enter the password required for Telnet configuration and Web Manager
access.
Advanced
ARP Cache Timeout
(secs)
When the unit communicates with another device on the network, it adds
an entry into its ARP table.
ARP Cache timeout
defines the number of
seconds (0-600) before it refreshes this table. 0 disables ARP Cache
Timeout. The default setting is 600.
TCP Keepalive
(secs)
Defines how many seconds the unit waits during an inactive connection
before checking its status. If the unit does not receive a response, it drops
that connection. Enter a value between
0
and
65
seconds.
0
disables
keepalive. The default setting is
45
.
Monitor Mode @
Bootup
Select
Disable
to disable entry into the monitor mode using the
yyy
or
xx1
key sequence at startup. This field prevents the unit from entering monitor
mode by interpreting the stream of characters that are received during the
device server's initialization at startup.
HTTP Server Port
This option allows the configuration of the web server port number. The
valid range is 1-65535. The default setting is
80
.
Config Server Port
Not applicable for this product.
MTU Size
The Maximum Transmission Unit (MTU) is the largest physical packet size
a network can transmit for TCP and UDP. Enter between
512
and
1400
bytes. The default setting is
1400
bytes.
TCP Re-
transmission
timeout (ms)
The desired TCP re-transmission timeout value. If the ACK is not received
for a packet sent from the XPress DR+ device, then the unit will retransmit
the data. The valid range is 500-4000 msec. Default is 500 msec.
3. When you are finished, click the
OK
button.
4. To save and reboot, on the main menu, click
Apply Settings
.
Host List Configuration
The XPress DR+ scrolls through the host list until it connects to a device listed in the host list
table. After a successful connection, the unit stops trying to connect to any others. If this
connection fails, the unit continues to scroll through the table until the next successful connection.
The host list supports a minimum of 1 and a maximum of 12 entries. Each entry contains an IP
address and a port number.
Note:
The host list is disabled for Manual and Modem Mode. The unit does not accept a
data connection from a remote device when the host list option is enabled.
To configure the unit's host list:
1.
On the main menu, click
Hostlist
.