10: Firmware Upgrades
XPress™ DR Industrial Device Server User Guide
62
Figure 10-1 TFTP Dialog Box
The unit performs a power reset after the firmware has been loaded and stored.
Distributing Firmware to Another Unit
To distribute firmware to another unit over the network:
1. Enter the host unit's Monitor Mode (see Monitor Mode).
2. Send the firmware to the receiving unit using the SF command, where x.x.x.x is the receiving
unit's IP address: SF x.x.x.x
The receiving unit performs a power reset after the firmware has been loaded and stored.
Note:
You can only update your unit 's internal Web interface using TFTP or DeviceInstaller.
Using HyperTerminal
The following procedure is for using the HyperTerminal software application. In some cases, the
HEX format file is available for download at
Before you can load firmware through the serial port you need to convert the ROM code to HEX
format. There is a DOS application, R2H.EXE that can be used to convert the ROM file to HEX
format. The R2H.EXE application is available at ftp://ftp.lantronix.com/pub.
Put R2H.EXE and the *.ROM file into the same directory on a PC then open a DOS Window to
that directory and type: C:\ R2H
filename
This will create a filename.hex file that you can load via the serial port.
Note:
Do not switch off the power supply during the update
. A loss of power while
reprogramming will result in a corrupt program image and a nonfunctional unit.
To download firmware from a computer via the unit’s serial port:
1. Enter Monitor Mode via the serial port. (see Monitor Mode).
2. Download the firmware to the unit using the
DL
command.
3. Select
Send Text File
and select the *.HEX file to be downloaded. The downloaded file must
be the
.HEX