6: Configuration via Telnet or Serial Port (Setup Mode)
XPress™ DR Industrial Device Server User Guide
44
7 Defaults
8 Exit without save
9 Save and exit Your choice ?
Serial Port Connection
If you want to initially configure the unit through a serial connection, follow these steps:
1. Connect a console terminal or PC running a terminal emulation program to your unit's serial
port. The default serial port settings are 9600 baud, 8 bits, no parity, 1 stop bit, no flow
control.
2. To enter Setup Mode, cycle the unit's power (power off and back on). After power-up, the
self-test begins and the red Diagnostic LED starts blinking.
You have one second
to enter
three lowercase
x
characters (
xxx
).
Note:
The easiest way to enter Setup Mode is to hold down the
x
key at the terminal (or
emulation) while powering up the unit.
3. At this point, the screen display is the same as when you use a Telnet connection. To
continue with a serial port login, go to
Exiting Setup Mode
There are two options through which to exit setup mode:
To save all changes and reboot the device, select option
9 Save and exit
from the Change
Setup menu. All values are stored in nonvolatile memory.
To exit the configuration mode without saving any changes or rebooting, select option
8 Exit
without save
from the Change Setup menu.