Chapter 9: Setup Mode: Channel Configuration
XPress DR+ User Guide
71
Flow
Flow control sets the local handshaking method for stopping serial input/output.
Flow (0) ? _
Use the following table to select flow control options:
Table 9-3. Flow Control Options
Flow Control Option
Hex
No flow control
00
XON/XOFF flow control
01
Hardware handshake with RTS/CTS lines
02
XON/XOFF pass characters to host
05
Port Number
The setting represents the source port number in TCP connections. It is the number that
identifies the channel for remote initiating connections.
Port No (10001) ? _
The default setting for port 1 is
10001
. The default setting for Port 2 is
10002
. The range
is 1-65535, except for the following reserved port numbers:
Table 9-4. Reserved Port Numbers
Warning:
We recommend that you not use the reserved port numbers for
this setting as incorrect operation may result.
Use Port
0
for the outgoing local port to change with each connection. The port range is
50,000 to 59,999. Each subsequent connection increments the number by 1 (it wraps
back around to 50,000).
Only use this automatic port increment feature to initiate a connection using TCP. Set the
port to a non-zero value when the unit is in a passive mode or when using UDP instead
of TCP.
Port Numbers Reserved for
1 – 1024
Reserved (well known ports)
9999
Telnet setup
14000-14009
Reserved for Redirector
30704 Reserved
(77F0h)
30718 Reserved
(77FEh)