4: Configuration Using Web Manager
WiPort® NR Embedded Device Server User Guide
21
Figure 4-5. Channel Serial Settings
2. In the available fields, enter the following information:
Channel 1
Disable Serial Port
Available on Channel 2 settings only. When selected, disables
communication through the serial port.
Note:
Using a telnet session you may enter a baud rate of 00
in channel settings to disable the serial port.
Port Settings
Protocol
Select the protocol type from the pull down menu for the
selected channel.
Flow Control
Flow control manages data flow between devices in a network
to ensure it is processed efficiently. Too much data arriving
before a device is prepared to manage it causes lost or
retransmitted data.
Baud Rate
The unit and attached serial device, such as a modem, must
agree on a speed or baud rate to use for the serial connection.
Valid baud rates are 300, 600, 1200, 2400, 4800, 9600
(default), 19200, 38400, 57600, 115200, 230400, 460800, or
921600.
Note:
Baud rates 460800 and 921600 are available for
selection only when CPU performance mode is set to High.
Data Bits
Indicates the number of bits in a transmitted data package.