Configuration via Serial Mode or Telnet Port
WiPort™ User Guide
59
Enable Enhanced Password (Y) ? _
The Y (Yes) option allows an extended security password of 16-characters for
protecting Telnet access.
Disable Port 77F0 (Hex)
Port 77F0 is a setting that allows a custom application to query or set the eleven
WiPort configurable pins when they are functioning as general purpose I/O (GPIO).
Disable this capability, if desired, for security purposes.
Disable Port 77F0h ? _
The default setting, the
N
(No) option, enables GPIO control. The
Y
(Yes) option
disables the GPIO control interface.
Factory Defaults
Select
7 Factory Defaults
from the Change Setup menu to reset the unit’s Channel
1 configuration, Channel 2 configuration, E-mail settings, and Expert settings to the
factory default settings. The server configuration settings for IP address, gateway IP
address, and netmask remain unchanged. The configurable pins’ settings also
remain unchanged. The specific settings that this option changes are listed below:
Channel 1 Configuration
Baudrate
9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C, no flow
control)
Port No
10001
Connect Mode
C0 (always accept incoming connection; no active
connection startup)
Hostlist Retry Counter
3
Hostlist Retry Timeout
250 (msec)
Send Character
0x0D (CR)
All other parameters
0
Channel 2 Configuration
Baudrate
9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C, no flow
control)
Port No
10002
Connect Mode
C0 (always accept incoming connection; no active
connection startup)
Hostlist Retry Counter
3