Lantronix M/GE-ISW 01 Series User Manual Download Page 20

Lantronix

 

 

         M/GE-ISW-xx-01 User Guide

 

33627 Rev. D 

           

http://www.lantronix.com/ 

Page 20 of 21 

Compliance Information 

Declaration of Conformity 

Manufacture’s Name: Lantronics, Inc. 
Manufacture’s Address: 48 Discovery, Suite 250, Irvine, California 92618 USA 
Declares that the products: 
M/GE-ISW-SFP-01, M/GE-ISW-SX-01, M/GE-ISW-LC-01, M/GE-ISW-LX-01 
Conform to the following Product Regulations: 
FCC Part 15 Class A, EN 55032:2012, EN 55024:2010 
Directive 2014/30/EU  
Low-Voltage Directive 2014/35/EU 
IEC /EN 60950-1:2006+A2:2013 
2011/65/EU EN 50581:2012 
With the technical construction on file at the above address, this product carries the CE Mark 
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) 

and Standard(s). 
Place: Irvine, California 
Date: April 27, 2022 
Signature: 

Fathi Hakam

 

Full Name: Fathi Hakam 
Position: Vice President of Engineering 

FCC regulations 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant 

to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful 

interference when the equipment is operated in a commercial environment. This equipment generates, 

uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 

instruction manual, may cause harmful interference to radio communications. Operation of this equipment 

in a residential area is likely to cause harmful interference, in which case the user will be required to 

correct the interference at the user's own expense. 

Canadian regulations 

This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on 

the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables 

aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique 

édicté par le ministère des Communications du Canada. 

Summary of Contents for M/GE-ISW 01 Series

Page 1: ...M GE ISW xx 01 Hardened Mini Gigabit Stand Alone Media Converters User Guide Part Number 33627 Revision D February 2023...

Page 2: ...of our domestic and international sales offices go to www lantronix com about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to update the inf...

Page 3: ...ns 6 Copper and Fiber Ports 8 Connect Fiber Cables 9 Connect the Twisted Pair Copper Cable 9 Connecting Power 10 Operation 11 Status LEDs 11 Fiber Port Mode at Power Up 11 Product Features 12 Cable an...

Page 4: ...applications The M GE ISW xx 01 is ideal for extending Ethernet over fiber to outdoor security cameras Ordering Information Model Description M GE ISW SX 01 Hardened Mini 10 100 1000Base T to 1000Bas...

Page 5: ...The illustration below shows the M GE ISW xx 01 in an example configuration with a security camera Package Contents Check that your package contains the following items Contact your point of purchase...

Page 6: ...Rail Mounting kit as described in the following sections It can also be mounted in the M MCR 01 Mini Chassis see the related manual for details Installing Industrial Velcro The industrial Velcro strip...

Page 7: ...e media converter 1 Position the DIN Rail Clip to the side of the media converter as shown below 2 Position the 4 40 screw to attach the DIN rail to the media converter as shown above right 3 Insert a...

Page 8: ...GE ISW xx 01 User Guide 33627 Rev D http www lantronix com Page 8 of 9 Copper and Fiber Ports The M GE ISW xx 01 front panels are shown below M GE ISW SFP 01 M GE ISW SX 01 same as M GE ISW LX 01 M G...

Page 9: ...ale RX cable connector to the female TX port Connect the Twisted Pair Copper Cable The AutoCross feature allows either MDI straight through or MDI X crossover cable connections to be configured automa...

Page 10: ...ck accepts 24 14 gauge wire 1 Turn OFF the main power source 2 Strip the power wires to the proper strip length 3 Loosen the two screws in the Terminal Block See figure below 4 Insert the power wires...

Page 11: ...nk and activity status Green On 1000BASE X or 100Base FX fiber link OK Green Flash 1000BASE X or 100Base FX fiber link OK and activity Off Fiber link down Copper Link Act Copper port link and activity...

Page 12: ...In a scenario where an auto negotiation device is linked to a non negotiating device the negotiating device via parallel detection recognizes the speed of that second device then establishes the best...

Page 13: ...es Diagnostic and Active Upon power up the media converter enters the Diagnostic state In the Diagnostic state the link for each of the media converter s ports can come up independently of each other...

Page 14: ...ent the M GE ISW xx 01 media converters extend network distances by segmenting collision domains so that the 512 Bit Rule applies separately to each collision domain In a full duplex Ethernet or Fast...

Page 15: ...Transmitter Power min 9 5 dBm max 3 0 dBm Fiber Optic Receiver Sensitivity min 20 0 dBm max 3 0 dBm Link Budget 10 5 dB M GE ISW LC 01 850 nm multimode Fiber Optic Transmitter Power min 9 0 dBm max 4...

Page 16: ...rnet connections require four wire pairs Cat 5e is the minimum for 1000 Mbps Category 6 cable commonly referred to as Cat 6 is a standardized cable for Gigabit Ethernet and other network physical laye...

Page 17: ...the patch panel and the wall jack plus 10 meters 33 ft of stranded patch cable between each jack and the attached device Since stranded cable has higher attenuation than solid cable exceeding 10 meter...

Page 18: ...nicast MAC addresses 1K Dimensions width x depth x height 1 8 x 3 33 x 0 8 45 7mm x 84 5 mm x 20 3 mm Weight 0 40 lbs 0 18 kg Power Consumption 1 2W Power Source 12 48 VDC or 22 36 VAC 10 Operating Te...

Page 19: ...iate power Contact Tech Support YES Proceed to step 2 2 Is the RX copper link LED lit NO Check the twisted pair copper cables for proper connection See Connect the Twisted Pair Copper Cable on page 9...

Page 20: ...een tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference...

Page 21: ...es measures sp cifiques appropri es In accordance with European Union Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 Lantronix will accept post usage returns of...

Page 22: ...rters 48 Discovery Suite 250 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support https www lantronix com technical support Sales Offices For a current list...

Reviews: