Lantronix
M/GE-ISW-xx-01 User Guide
33627 Rev. D
Page 18 of 19
Troubleshooting Cat 6 & Cat 6A Structured Copper Cabling Systems
If a Category 6 cabling system does not meet the electrical requirements for supporting 10GBASE-T
applications, see the TSB-155 provides guidelines designed to mitigate the alien crosstalk between the
target pair and the disturbing pairs of Category 6 channels and permanent links. Annex B of TSB-155
outlines the following mitigation actions most appropriate for individual situations:
•
Use Category 6 shielded or Category 6A patch cords;
•
Replace Category 6 connectors with Category 6A connectors;
•
Use non-adjacent patch panel positions;
•
Separate equipment cords and patch cords;
•
Unbundle or more loosely bundle the horizontal cabling; and
•
Reconfigure the cross-connect as an interconnect.
Technical Specifications
For use with M/GE-ISW-xx-01 media converters.
Standards Compliance
IEEE802.3
Regulatory Compliance for Emission
FCC Class A; EN55022 Class A
Regulatory Compliance for Immunity
EN55024
Safety Compliance
CE Mark
Data Rate
RJ-45: 10 Mbps, 100 Mbps, and 1000 Mbps
SFP: One 100/1000BASE-X dual speed SFP slot
Max Frame Size
10,240 bytes
Unicast MAC addresses
1K
Dimensions (width x depth x height)
1.8” x 3.33” x 0.8”(45.7mm x 84.5 mm x 20.3 mm)
Weight
0.40 lbs (0.18 kg)
Power Consumption
1.2W
Power Source
12 - 48 VDC or 22-36 VAC ±10%
Operating Temp
-40°C to +75°C
(-40°F to +167°F)
Humidity
5% to 95%, non-condensing
Operating Humidity
5% to 95% (non-condensing)
Altitude
0-10,000 feet
MTBF
*
Greater than 41,680 hours
((MIL-HDBK-217F)
Greater than 114,580 hours
(Bellcore7 V5.0)
Warranty
Lifetime
*
MTBF calculation is based on use with a 50,000 hour power supply.
CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485,
DS1, DS3, Video Coax, etc., are intended to be connected to intrabuilding (inside plant) link segments
that are not subject to lightening transients or power faults. Copper-based media ports, e.g., Twisted Pair
(TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to
interbuilding (outside plant) link segments that are subject to lightening transients or power faults. Failure
to observe this caution could result in damage to equipment.
WARNING: Visible and invisible laser radiation when open. Do not stare into the beam or view directly
with optical instruments. Failure to observe this warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments, or the performance of procedures other than those specified
herein could result in hazardous radiation exposure.