7: Network, Line, Tunnel, and Terminal Settings
EDS Device Servers User Guide
67
Figure 7-10. Tunnel – Disconnect Mode Page
Tunnel – Disconnect Mode Page
Tunnel –
Disconnect
Mode Page
Settings
Description
Character
Stop
If enabled, an active connection is disconnected when the specified stop
character is read on the serial line.
Modem
Control
If enabled, an active connection is disconnected when the Modem
Control pin (DSR) is de-asserted on the serial line.
Timeout
Enter the idle time, in milliseconds, that must elapse for a connection
before it is disconnected. Enter 0 (zero) to disable (default).
Flush Serial
Data
Select whether the serial line should be flushed when a connection is
disconnected. Choices are:
Enabled
= flush the serial line when a connection is disconnected.
Disabled
= do not flush the serial line. (
default
)
Summary of Contents for EDS16PR