GPS/GLONASS Receiver Module A5100-A User Guide
34
9
Quality and Reliability
9.1 Environmental Conditions
Operating temperature
-
40 … +85
C
Operating humidity
Max. 85% r. H., non-condensing, at 85
C
MSL JEDEC (Moisture Sensitivity Level) 3
Storage
6 months in original package.
Table 10: Environmental conditions
9.2 Product Qualification
Prior to product qualification the GPS&GLONASS receiver is preconditioned accord-
ing to EIA/JEDEC standard JESD22-A113-B / Level 3.
Basic qualification tests:
•
MSL Classification according to J-STD-020C (MSL3 @ 245°C)
•
MSL Rework Compatibility according to J-STD-020C
•
Temperature Cycling
–40°C … +85
C
•
Temperature Humidity Bias 70
C / 85% RH
•
Low / High Temperature Operating
–40°C / +85
C
•
High Temperature Operating Life +85
C
•
Vibration Variable Frequency
•
Mechanical Shock
Please contact Lantronix for detailed information.
9.3 Production Test
Each module is electrically tested prior to packing and shipping to ensure state of the
art GPS&GLONASS receiver performance and accuracy.