Troubleshooting 

 

 

 

Verify that you are using the included or appropriate power cord/adapter. 

D

on’t use the power adapter with DC output higher than the power rating 

of the device. Otherwise, the device will burn down. 

 

Select the proper UTP/STP cable to construct your network. Please check 

that  you  are  using  the  right  cable.  Use  unshielded  twisted-pair  (UTP)  or 

shielded twisted-pair (STP) cable for RJ-45 connections: 100

Ω

  Category 

3,  4  or  5  cable  for  10Mbps  connections,  100

Ω

  Category  5  cable  for 

100Mbps, or 100

Ω

  Category 5e/above cable for 1000Mbps connections. 

Also  be  sure  that  the  length  of  any  twisted-pair  connection  does  not 

exceed 100 meters (328 feet). 

 

Diagnosing LED Indicators:

 The Switch can be easily monitored through 

panel indicators, which describes common problems you may encounter 

and  where  you  can  find  possible  solutions,  to  assist  in  identifying 

problems. 

 

IF the power indicator does not light on when the power cord is plugged in, 

you  may  have  a  problem  with  power  cord.  Then  check  for  loose  power 

connections,  power  losses  or  surges  at  power  outlet.  If  you  still  cannot 

resolve the problem, contact your local dealer for assistance. 

 

If the Industrial switch LED indicators function normal and the connected 

cables are correct but the packets still cannot transmit, please check your 

system

’s Ethernet devices’ configuration or status.

 

Summary of Contents for IPES-0016

Page 1: ...Lantech IPGS 0016 16 10 100 1000T Industrial Unmanaged PoE Ethernet Switch IPES 0016 16 10 100TX Industrial Unmanaged PoE Ethernet Switch User Manual V1 01 Mar 2022...

Page 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Page 3: ...fety Precaution 2 Hardware Description 3 Front Panel 3 Top View 4 Dimensions 4 Wiring the Power Inputs 6 Wiring the Fault Alarm Contact 6 LED Indicators 8 RJ 45 Pin Assignments 9 Cabling 11 Mounting I...

Page 4: ...Hardware Installation 15 Installation Steps 16 Troubleshooting 17...

Page 5: ...meets the high reliability requirements demanded by industrial applications Model Lists Model name 10 100 1000T ports 10 100TX ports PoE ports IPGS 0016 24V IPGS 0016 24V E 16 16 IPES 0016 24V IPES 0...

Page 6: ...acking List 1 x 16 port Industrial Ethernet Switch 1 x Terminal Block Safety Precaution Attention If DC voltage is supplied by an external circuit please use a protection device on the power supply in...

Page 7: ...DC DC converter between the power supply and the Ethernet switch on all Non Isolated units Please contact the sales team for advice on which units support isolated power supply In this paragraph we w...

Page 8: ...ront Panel of the Industrial Switch Top View The top panel of the Industrial Switch is equipped one terminal block connector of two DC power inputs Top panel of the Industrial Switch Converter Dimensi...

Page 9: ...5 The dimensions of IPGS 0016 IPES 0016 are 74 x 152 x 105 mm W x H x D The figure below gives the dimensions and views of each side of the 16 port Industrial Ethernet Switch...

Page 10: ...al block connector 2 To tighten the wire clamp screws for preventing the DC wires to loose Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the pi...

Page 11: ...7 Note The wire gauge for the terminal block should be in the range between 12 24 AWG Insert the wires into the fault alarm contact No 3 4...

Page 12: ...input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional or no power inputs 1 16 Upper LED Green On Connected to network Flashing Networking is activ...

Page 13: ...e figures below for straight through and crossover cable schema 10 100Base TX Pinouts Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wir...

Page 14: ...below describes the gigabit Ethernet RJ 45 pinouts Pin Signal name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi directional pair B 4 BI_DC Bi directional pair C 5...

Page 15: ...a Cabling Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 100 Category 3 4 or 5 cable for 10Mbps connections 100 Category 5 cable for 100Mbps or 100 Category 5...

Page 16: ...the industrial switch when out of factory If not please refer to the following steps and figure to secure the DIN rail clip on the switch 1 Use the screws to screw on the DIN rail clip on the industri...

Page 17: ...1 First position the rear side of the switch directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail 2 Push the unit downward 3 Check the DIN Rail clip is t...

Page 18: ...Remove the DIN Rail bracket from the switch loose the screws to remove it 2 Place the wall mount bracket on the top side and bottom side of the switch 3 Use the screws to screw the wall mount bracket...

Page 19: ...15 Hardware Installation In this paragraph we will describe how to install the 8 port 10 100 1000Base TX Industrial Switch and the installation points for the attention...

Page 20: ...power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twiste...

Page 21: ...at the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators The Switch can be easily monitored through panel indicators which describes common problems y...

Reviews: