Adjustment Settings for Operators
243
9
❖
1-720-002 : Tray 2
• Max: 2 mm
• Min:-2 mm
• Step: 0.1 mm
• Initial value: 0
❖
1-720-003 : Tray 3
• Max: 2 mm
• Min:-2 mm
• Step: 0.1 mm
• Initial value: 0
❖
1-720-004 : Tray 4 LCT
• Max: 2 mm
• Min:-2 mm
• Step: 0.1 mm
• Initial value: 0
❖
1-720-005 : Tray 5 LCT
• Max: 2 mm
• Min:-2 mm
• Step: 0.1 mm
• Initial value: 0
❖
1-720-006 : Tray 6 LCT
• Max: 2 mm
• Min:-2 mm
• Step: 0.1 mm
• Initial value: 0
❖
1-720-007 : Tray 7 Bypass
• Max: 2 mm
• Min:-2 mm
• Step: 0.1 mm
• Initial: value 0
❖
1-720-008 : Duplex
• Max: 2 mm
• Min:-2 mm
• Step: 0.1 mm
• Initial: value 0