background image

- 4 -

Connection Terminals

Power

+

Power supply input, Positive wire.

-

Power supply input, Negative wire.

Relay

Output

NO

Normally Open port. the relay rating is 3A/240VAC; connect to the switch of
the electric lock or device.

COM

Common port. the relay rating is 3A/240VAC; connect to the switch of the
electric lock or device.

NC

Normally Close port. the relay rating is 3A/240VAC; connect to the switch of
the electric lock or device.

Notice :

Beside the SIMCard ,There is a RUN led, when the RTU5024 has registered to cellular network, The

RUN led will flash per second; if The RUN led is off, it indicates that the RTU 5024 can not connect to SIM

card or unregistered to the cellular network

5. Features

1. No call charges. The GSM Gate Opener rejects the call from authorized number then carries out

the turn ON/OFF action on the first 'ring;

2. It is no longer traditional to open the door, but it is more interesting to open the door by shaking

it.

3. Multiple applications. (gates, bollards, barriers, garage doors, shutters and access doors or

machines);

4. Secure - Using caller ID for identification, unknown callers are ignored;
5. Can be operated from anywhere, no distance limit;
6. Add or remove users by SMS Text command;
7. No need to provide a remote control for different users;
8. Up to 200 authorized phone numbers can be configured;
9. One output with relay rating 3A/240VAC for connecting the switch of the door or machines;
10. The relay action will return a SMS confirmation to the owner, this function is editable by user;

11.

Based on GSM Network, applied to many applications.

6. Settings(SMS Commands)

Notice:

1. The default Password is

1234

.

Summary of Contents for RTU5024

Page 1: ...or and Door opener Open gate or garage door with a FREE call from your mobile phone Remote switching machines with a FREE call from your mobile phone GSM Gate Opener GSM Remote Switch RTU5024 User Man...

Page 2: ...ntained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registered electrician be s...

Page 3: ...rejects the call from authorized number then carries out the turn ON OFF action 2 Safety Directions Safe Startup Do not use GSM SMS IR Controller when using GSM equipment is prohibited or might bring...

Page 4: ...r 1 second quickly registering to cellular network Flash per 2 seconds Normal status OFF can not connect to SIM card or unregistered to the cellular network Relay Relay Status calling in the relay wil...

Page 5: ...he GSM Gate Opener rejects the call from authorized number then carries out the turn ON OFF action on the first ring 2 It is no longer traditional to open the door but it is more interesting to open t...

Page 6: ...because in addition to the fact that other people may not know the number of the SIM inserted in it we also use a Password that makes it impossible for anybody who doesn t know it to access the system...

Page 7: ...any other character When input punctuation symbol must be under ENGLISH or DIGITAL input method Not support other input method 6 2 Setup Authorized number E g if you want to setup 13500001111 as the...

Page 8: ...umbers can access it or Allow User Numbers can access it only 6 7 Setup the relay close time Tips The time should be in 0 9 5seconds This command is useful in case you need to keep the relay closed or...

Page 9: ...SMS confirmation when Relay action Tips if you enable it when the relay action close or open the unit will return a SMS confirmation to you The first user number The return SMS is Relay ON Operated by...

Page 10: ...ame The mainframe should be installed in the position that person can not get it and there with a power source as well as enough GSM signal coverage 8 Technical specifications Rated Voltage 12VDC 1 A...

Page 11: ...If the remote control works but the Control Unit fails to send SMS texts switch the power of Control Unit off and switch it on after one minute Test this system after another minute or check the setti...

Page 12: ...11 The End Any questions please help to contact us feel free Made by Langjushan Tech langjushan tech hotmail com 17324422003...

Reviews: