11. If the command is incorrect, the RTU5024 will return: Command error, please resend command

So please check the Command, or add the country code before the telephone number or check
the input is in ENGLISH INPUT METHOD and CAPS LOCK.

12. The SMS commands that you will certainly use in the GSM Gate Opener are the following:

6.1 Setup New Password

RTU5035

if successful, the unit will return:

New Password:xxxx

.

For example, the original password is 1234, you want change it to 6666, then you can send the
command below:

1234#PWD6666#PWD6666#

Tips:

1.The

pwd

in the commands is means the password, when you use it, please in stand of it by

the digital number, the capital letters

PWD

is the command letter, use

PWD

directly.

2.Remember that commands must be

CAPITAL Lock LETTERS

. It is PWD not pwd, CAP not Cap

etc. Don't add spaces or any other character. When input punctuation symbol #, must be
under ENGLISH or DIGITAL input method. Not support other input method.

6.2 Setup Authorized number

E.g.: if you want to setup 13500001111 as the first user number, and the password is 1234,then you
can send

1234#TEL004413500001111#001#

to the RTU5024 unit. After the RTU5024 received, the

0044 is country code, will return:

Tips:

1. the authorized number means the one who can dial the RTU5024 unit to open it.

2.We strongly recommend that the serial number of 01 is cellphone number, because of the

Relay action message only send to the first position number;

3. The Serial Number is the position to store the authorized number, from 001~200.

6.3 Inquiry the Serial Number’s Authorized number

E.g.: If you want to know the authorized number at position 2, and the password is 1234,then you can
send

1234#TEL002?

to check it.

pwd#PWDnewpassword#PWDnewpassword#

pwd#TELAuthorized Number#Serial Number#

001:004413500001111
002: Empty
003: Empty
004: Empty
005: Empty

pwd#TELSerial Number?

Summary of Contents for RTU5024

Page 1: ...or and Door opener Open gate or garage door with a FREE call from your mobile phone Remote switching machines with a FREE call from your mobile phone GSM Gate Opener GSM Remote Switch RTU5024 User Man...

Page 2: ...ntained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products We recommend that the advice of a registered electrician be s...

Page 3: ...rejects the call from authorized number then carries out the turn ON OFF action 2 Safety Directions Safe Startup Do not use GSM SMS IR Controller when using GSM equipment is prohibited or might bring...

Page 4: ...r 1 second quickly registering to cellular network Flash per 2 seconds Normal status OFF can not connect to SIM card or unregistered to the cellular network Relay Relay Status calling in the relay wil...

Page 5: ...he GSM Gate Opener rejects the call from authorized number then carries out the turn ON OFF action on the first ring 2 It is no longer traditional to open the door but it is more interesting to open t...

Page 6: ...because in addition to the fact that other people may not know the number of the SIM inserted in it we also use a Password that makes it impossible for anybody who doesn t know it to access the system...

Page 7: ...any other character When input punctuation symbol must be under ENGLISH or DIGITAL input method Not support other input method 6 2 Setup Authorized number E g if you want to setup 13500001111 as the...

Page 8: ...umbers can access it or Allow User Numbers can access it only 6 7 Setup the relay close time Tips The time should be in 0 9 5seconds This command is useful in case you need to keep the relay closed or...

Page 9: ...SMS confirmation when Relay action Tips if you enable it when the relay action close or open the unit will return a SMS confirmation to you The first user number The return SMS is Relay ON Operated by...

Page 10: ...ame The mainframe should be installed in the position that person can not get it and there with a power source as well as enough GSM signal coverage 8 Technical specifications Rated Voltage 12VDC 1 A...

Page 11: ...If the remote control works but the Control Unit fails to send SMS texts switch the power of Control Unit off and switch it on after one minute Test this system after another minute or check the setti...

Page 12: ...11 The End Any questions please help to contact us feel free Made by Langjushan Tech langjushan tech hotmail com 17324422003...

Reviews: